“Fire door keep locked” is the sign for a small, locked cleaner’s cupboard. On which side of the door must it be fixed?

A

Outside

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Is this statement true or false? Minor amendments can be made to a door closer’s fixing position without invalidating its performance and fire test evidence.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Why would a door closer slam a door closed?

A

The closer has lost its hydraulic fluid
The hydraulic valves have not been adjusted

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What’s the maximum delay allowed in BS EN 1154 (from fully open to fully closed) on a delayed action closer fitted to a fire door?

A

25 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Is the following statement true or false? A mortice lock on a 1 hour fire door will need an intumescent gasket, but this is not necessary on a ½ hour door.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A cylinder rim nightlatch and its box strike are surface fixed, so they don’t need any intumescent protection. Is this always true?

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In what circumstances can you fix a letterplate to a fire door?

A

If there’s fire test evidence for it

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Floating spindles are not…..

A

fixed to the operating furniture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the benefits to bolt-through fixings?

A

More durable in daily use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is required to hold a fire door closed?

A

All fire doors need either a closer or a lock to hold them closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Under what circumstances might a surface fixed item pose a risk to a fire door?

A

If it has bolt-through fixings
If it wraps around the edge of the door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What might stop a latch on a fire escape door from closing on its strike?

A

Door dropped
Door/frame gap too tight
Strike tongue not angled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Is the following statement true or false? All fire doors need a latch to hold them closed.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What’s the name of the document which gives detailed guidance on door hardware for fire and escape doors?

A

Code of Practice: Hardware for fire and escape doors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Is this statement true or false? If a door is installed as a fire door, then the position of the hinges must be the same as when it was fire tested.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the essential ironmongery for a door sign Fire Door Keep Shut?

A

Hinges
Door Closer
Operating furniture
Signage

17
Q

The recommended fixing height for fire doors signs is?

A

1.5 m from ffl

18
Q

A chippy says he’s heard that you can fix any CE marked closer in parallel arm mode, and asks you if that is right. What is the correct answer to this question?

A

Not necessarily, it depends on what the fixing instruction says

19
Q

Indicate the reasons why a door closer might not close a door.

A

The closer is too weak
The latch is not riding over the strike
The strike is not correctly angled
The door has dropped

20
Q

Is the following statement true or false? Retro-fitted digital code locks don’t need fire test evidence.

A

False

21
Q

How do you do a maintenance check on an electro-magnetic hold open or swing free door closer?

A

Turn off its electrical supply

22
Q

What is the essential ironmonger for a door signed Fire Door Keep Locked?

A

Lock
Operating furniture
Signage
Hinges

23
Q

Which of these materials requires a longer fixing screw of up to 50 mm for hinges?

A

Graduated Density Core

24
Q

A 1 hour fire door to a store has a deadlock fitted, to keep it locked shut. There is no door closer. Is this acceptable?

A

Yes

25
Q

“Automatic fire door keep clear” signs (for doors which are electro-magnetically held open, or swing free) should be fixed to

A

On both sides

26
Q

Lever furniture used on self-closing doors should meet which category of use grade in BS EN 1906?

A

Grade 3

27
Q

The blue colour of fire door signs means that they are

A

Mandatory