when installing a septic tank u can use a gravity system if ____ ..
field is lower than the outlet of the tank
when the field is above the inlet of the septic tank what must u use
a pump
what could be the problem if boiler safety relief valve keeps discharging
failure of pressure reducing valve or faulty aquastat
what do u require on a cooling tower
water softener, rp, pressure vacuum breaker, and air gap
what type of heater can be use when theres not enough room for fin
kick space heater
what connectors does a chiller use
flexible flanged connectors
on recessed forced flow heating install thermostat on
return air next to the unit
best location for a wild loop in heating
inside doorways (vestibules)
wiring on submersible should be strapped every
10ft
pipe from pitless adapter should be graded ____ …
up towards the house
1) when troubleshooting pump there is high amperage, what is the problem
2) low amperage ?
3) no amperage ?
1) high amp means impeller is stuck so the pump is working too hard
2) low amp means theres low water in well, impeller is broken or venture is plugged
3) no amp means defective pressure switch, switch tube might be plugged
when there is cavitation what could be the problem w the pump
pump is working above max lift capacity, and there’s a pressure difference between inlet/outlet
standard pressure tank is ___ air and ___ water
1/3 air and 2/3 water
what is a common problem when there is hardness in the water
there is calcium and magnesium
degrees of hardness in water starts from very soft at 0 - ____ and adds ____ every time it gets harder
0-50, adds 50 to get to next level of hardness and so on ex. mid soft is 50-100 mid hard is 100-150 etc
temporary hardness settles at ___ deg C
permanent hardness at ___ deg C
temp hardness - 60 deg C
perm hardness - 140 deg C
what causes back siphonage ? it might happen to a hose bib so what does it require
negative pressure in the system, like a vacuum. so hose bibs require a vacuum breaker
test pressure for medical gas
150psi or 1 and a half times its working pressure whichever is greater for 24 hours
if flush valve has a long flush it could be because of a
dirty/plugged bypass
distance of soil from edge of trench
1m or 3’3”
max heigh of rp to floor
5 feet
if a zone valve is noisy it was probably installed ___
backwards
where do u install mitigated radon pipe
under slab
interior leaders and sows must have a cleanout where?
3m upstream from the bottom of the leader or stack
when doing a ball test what are the min. diameters for the ball
50mm for pipes 3 inches or more
25mm for pipes less than 3 inches
minimum trap arm length of unvented fixture drain
also the standard height of the trap arm for a lavatory
18 inches or 450mm
minimum trap fixture drain
2”
max height from manhole taper
1m
what to do if hot water pipe is longer than 30m or extend 4 storeys ?
provide recirculation