Installation and Troubleshooting of Domestic Refrigerators and Freezers Flashcards
When a refrigerator-freezer has a hot-wall condenser, the unit should be at least ____ form the surrounding surfaces.
2”
A refrigerator-freezer thermostat should always be connected into the ____ wire.
hot (ungrounded)
Wiring that is used to ground appliances and electrical circuits should be ____ colored.
green
When comparing open-circuit voltage to the voltage when the unit is running, the open-circuit voltage should be no more than ____.
5 V higher
In a capillary tube system, more refrigerant entering the evaporator than there is heat available to vaporize it may result from a(n) ____.
overcharge of refrigerant
Continuous running, no refrigeration, or a condenser that is cooler than normal may indicate a restriction in what devices?
Capillary Tube
Filter-Drier
Screen on the high side
Rather than using piercing valves, an alternative method of connecting gauges and charging cylinders to a hermetic system is to use ____.
valve adapters
When a domestic appliance’s metering device is clogged with wax, replace the ____.
filer-drier and metering device