Industrial Estate, Cambridge Flashcards

1
Q

What type of measurement did you undertake for Cambridge Industrial property?

A

GIA basis - Code of Measuring Practice

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What type of instrumentation did you use to collect data for the Cambridge Property?

A

Distometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How did you undertake the measurement?

A
  • Walk around the site - improved understanding of building shape.
  • Utilise the existing floor plans
  • Used distometer to measure from the inside of one exterior wall to opposite exterior wall. Where internal walls interrupted a clear measurement, measure to the wall and then note the thickness of the wall and continue measurement on the other side.
  • Calculation - Length x Width = Size (Sqm).
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is ancillary office space?

A

Office space located within a building which primary use is for industrial use.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Why did you verify against floor plans and marketing details?

A

To assess margin of error (2%).

These areas were previously assumed during a measured survey.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What was excluded in the GIA measurement?

A

Open balconies

Open fire escapes

Parking areas

Covered ways

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What did you include in the GIA measurement?

A

Walls and Partitions

Toilets, showers, changing rooms

Columns

Plant rooms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How do you calibrate a laser measurer?

A

My company send distometers off to to calibrate the lasers (LEICA)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How did you ensure your measurement was as accurate as possible?

A

taking several check measurements

making sure the laser or tape is measuring from the correct surfaces

checking measurements with scaled plans or reliable mapping software

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Tell me about a strength and weakness of a measuring technique you have used.

A

Distometer

Weaknesses - Do not work well in sunlight

Strengths - Tent to be accurate to 1.5mm up to 200 mm.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly