Image evaluation Flashcards

1
Q

Which technical factor is used to alter radiographic contrast?

A

kVp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Each square picture element in a digital viewing monitor is called a?

A

pixel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The geometric factors that affect the formation of the image are 1. SID 2. OID 3. focal spot

A

1.SID 2.OID 3.focal spot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The maximum heat capacity of the anode of the x-ray tube is rated in terms of?

A

heat units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the purpose of the filament circuit?

A

supplies the heat required by the x-ray tube filament for thermionic emission of electrons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the correct exposure time required to produce 50 mAs when using 200 mA station?

A

0.25 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which of the following components is located on the low voltage side of the x-ray circuit? 1. kVp selector 2. autotransformer 3. step-up transformer

A

1.kVp selector 2.autotransformer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The greatest spatial resolution will be produced when the matrix is ________ and the pixels are _____.

A

large ; small

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Contrast is directly influenced by 1. SID 2. fog 3. collimation

A

2.fog 3.collimation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which of the following tells the operator that the correct exposure has been received by the phosphors in the imaging plate?

A

exposure indicator number

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which of the following X-ray generators produces the greatest amount of x-rays for the same exposure technique?

A

high frequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which of the following will increase spatial resolution? 1. Increase SID 2. Increase OID 3. Decrease in focal spot size

A

1 and 3 only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The overall darkness or blackness in an image is referred to as?

A

density

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When it is necessary to differentiate tissues with similar tissue densities, which of the following image quality factors is most desirable?

A

High contrast

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which of the following transformers reduces the voltage on the secondary side to provide an appropriate current to heat the filament?

A

Step- down transformer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Which of the following pathologic conditions require a decrease in exposure technique? 1. multiple myeloma 2. emphysema 3. osteoporosis

A

1, 2 and 3

17
Q

Which of the following is the function of the autotransformer? 1. Provides the means for variable kVp selection 2. Provides compensation for fluctuations in the incoming line voltage 3. Supplies power to the other parts of the x-ray circuit

A

1,2 and 3

18
Q

A charged coupled device (CCD) is used in an indirect conversion DR system to?

A

Convert light to an electrical signal

19
Q

Which control on the viewing station controls the density or brightness of an image?

A

Window level

20
Q

Which of the following if increased, will result in increased radiographic density? 1. increased mA 2. increased exposure time 3. increased kVp

A

1,2 and 3

21
Q

Which of the following is located on the low-voltage side of the x-ray circuit and functions to measure the voltage output from the autotransformer?

A

exposure timer

22
Q

Which quality factor is a key to visibility of detail?

A

Focal spot size