which of the controls listed below, controls the gas pressure to the main burner, the temperature of the water, and turns off the gas when the pilot goes out.
a) ECO
b) temperature and pressure relief valve
c) aquastat
d) unitrol
d) unitrol
the components of a copper fin tube, instantaneous water heater are :
a) anti-scald device and a pump control
b) pump, pump control, flow switch temperature and pressure relief valve, and a limit control.
c) ECO temperature and pressure relief valve anonde, and a dip tube
d) temperature and pressure relief valve anode and a limit control
b) pump, pump control, flow switch temperature and pressure relief valve, and a limit control.
what does ECO Stand for
Energy control shut off device
the minimum allaowable distance to be maintained from a 50,000 btuh water heater outlet to a gas utility service regulator vent opening is
a) 1’ (300mm)
b) 2’ (600mm)
c) 3’ (900mm)
d) 6’ (1800 mm)
c) 3’ (900mm)
the minimum allowable distance to be to be maintained from a 50,000 btuh water heater flue outlet to a building opening is
a) 6” (150mm)
b) 12” (300mm
c) 2’ (6)00mm)
d) 3’ (900mm)
b) 12” (300mm)
the minimum allowable distance to be maintained from a 50,000 Btuh water heater flue outlet to a building opening is
a) 6” (150mm)
b) 12” (300mm
c) 2’ (6)00mm)
d) 3’ (900mm)
b) 12” (300mm)
what must be done to ensure equal water flow through two water heaters when they are paired together
a) install flow balancing cocks
b) ensure they are installed on the same vertical plane
c) ensure the inlet and outlet piping are equivalent lengths
d) install a mixing valve and two water regulators
c) ensure the inlet and outlet piping are equivalent lengths
What will cause a E.C.O to Open
a) a defective thermostat
b) long draws of water
c) a dip tube which is to short
d) too low of thermostat settings
a) a defective thermostat
Which of the following is used to de-lime a water heater
a) backing soda
b) tri-sodium phosphate
c) lemon juice
d) muriatic acid
d) muriatic acid
the most likely cause of a puddle of water at the side of a water heater where the drain cock and relief valve are located is that
a) the drain cock is opening intermittently
b) the relief valve is opening periodically
c) it is caused by condensation created when cold water enters the heater
d) the unitrol fitting is leaking and self re-sealing itself
b) the relief valve is opening periodically
a customer complains that the pilot goes out every once and a while. this is the second service call for this problem this month when the pilot is re-established, the closed circuit millivolt test stays at 14 millivolts. the magnet drops out at 4 millivolts what should be done next?
a) replace the gas valve because the magnet is weak
b) clean and adjust the pilot and burners
c) replace the thermocouple
d) check for another problem such as down draft or pilot position
d) check for another problem such as down draft or pilot position
what is the pressure relief valve setting for most residential type water heaters
a) 75 psig
b) 100 psig
c) 150 Psig
d) 200 Psig
c) 150 Psig
the device that water heaters use to direct the incoming water to the lower part of the tank is called
a) an anode
b) an anti-siphon device
c) a cathode
d) a dip tube
d) a dip tube
is it permitted to use water heaters for space heating only
a) yes
b) no
b) no
is leaded solder allowed on the heating portion of a combination domestic heating / hot water system
a) yes
b) no
b) no
the recommended water temperature setting from a mixing valve to the domestic water system in combination heating systems that enjoy oil-fired water heaters for heating potable water and for space heating
a) 43 C (110 F)
b) 49 C to 54 C (120 F to 130 F)
c) 60 C to 66C ( 140 F to 150 F)
d) 83 C (180F)
b) 49 C to 54 C (120 F to 130 F)