Hydraulics Flashcards

1
Q

Conversion factors

A
3/4 = 25
1 = 9
1 1/2 = 3.6
1 3/4 = 2 
3 = .67 (2/3)
3 1/2 = .4 (4/10)
4 = .25 (1/4)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Maximum pump pressures

A
booster line- 400
single jacket/ wildland- 200
double jacket- 300
double jacket high pressure- 600
Hard suction- 150
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

sprinkler PSI and gpm

A

25psi / 30GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Appliance loss PSI?

A

15 for deluge or monitor

25psi for standpipe, ladder pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

wildland tip sizes and gpm

A

3/16” - 7
1/4” - 13
3/8” - 30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Hand line tip sizes and gpm

A
1/2 - 50
5/8 - 80
3/4 - 120
7/8 - 160
1 - 210
1 1/8 - 270
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Master streams size and gpm

A
1 1/8 - 300
1 1/4 - 400
1 3/8- 500
1 1/2 - 600
1 3/4 - 800
2 - 1100
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Immediate pump pressure for hand lines?

A

gravity gain/loss plus nozzle pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

rule of 12’s gpm range?

A

180-320

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

friction loss rate from 0 to 170

A
<100 = 1 FLR
100 = 2
110 = 2
120 = 3
130= 3
140 = 4
150 = 5
160 = 5
170 = 6
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Intake pressure drop for 3, 2, 1 like lines

A

10% drop- 3 more like lines
15%- 2
25%- 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly