Hydraulics Flashcards
IOP Highway
125psi
IOP Blitz
125 psi
IOP Blitz / Wye / one line
130 psi
IOP Blitz / Wye / two lines
150 psi
IOP FDC Sprinklers
150 psi
IOP if not listed
125 psi
Max time to pull primer
30 secs
Foam Elkhart PSI @ what GPM minimum hose, max hose
200 psi @ 95 gpm, 100, 300
Foam Angus PSI @ what GPM
150 psi @ 95 gpm, 150, 300
Per SBCoFD Driver operator Manual. What type of Class B foam is recommended for type 1 and what is the coverage
1% AFFF, covers 300 sq ft, 20’ diameter circle, 17’x17’ square
FL per 100 1 3/4 @ 60,95,125,150,200
6, 14, 24, 35, 62
FL per 100 2 1/2 @ 95,125,150,200,250
2, 3, 5, 8, 13, 18,
FL per 100 3 @ 95,125,150,200,250,300,400,500
1, 1, 2, 3, 5, 7, 13, 20
Gallons per cubic ft
7.5
Pounds per cubic ft
62.5
cubic inches per gallon
231
volume of rectangle
LxWxH
volume of cyliner
6 x D ²x H
How many ft for relay pumping
700’ with extra 50 pulled for connections
IOP for relay pumping
130
simplest method for relay pumping
constant pressure method
minimum psi reading on intake gauge for relay pumping
20 PSI
main reason for the use of water
heat absorption
Types of pressure and their definition.
ATMOSPHERIC - 14.7 PSI AT SEA LEVEL (ALTITUDE)
HEAD - HEIGHT OF WATER (ELEVATION)
STATIC - STORED POTENTIAL ENERGY
NORMAL OPERATING - PRESSURE IN THE DISTRIBUTION SYSTEM DURING NORMAL HOURS
RESIDUAL - WHAT’S LEFT AFTER OVERCOMING FRICTION LOSS
FLOW - FORWARD VELOCITY PRESSURE