HVAC Quiz Review #2 Flashcards
A flow switch detects the water pressure in a hydronic system.
True or False
False
A boiler will vary the temperature of the water depending on the number of zones calling for heat.
True or False
False
A circulating pump could be controlled by an end-of-travel switch in a zone valve.
True or False
True
The low water cut-off switch and the flow switch on a boiler are “normally closed” devices designed to shut down the systems when triggered.
True or False
False
An aquastat and a high limit (in a boiler system) will both have the same temperature setting.
True or False
False
Zones in a boiler system could be controlled by either zone valves or seprate circulation pumps.
True or False
True
Which of the following zone valves would require a seprate relay to energize the boiler system.
a) 2-wire
b) 3-wire
c) 4-wire
c) 3-wire
Why will a boiler shut-down if the main circulation pump seizes?
a) No water flow means increase temperature in boiler, high limit trips
b) High water flow means decrease temperature in boiler, LWCO trips
c) No water flow means increase in temperature in zone, make-up water trips
d) High water flow extinguishes pilot burner, main burner goes out
a) No water will flow means increase temperature in boiler, high limit trips
In a combination heating/cooling systems, the main furnace blower is:
a) For heating only
b) For cooling only
c) For heating or cooling
d) Always 3 speeds - low, medium, and high
c) for heating and cooling
The refrigerant leaving the evaporator coil is a:
a) Low pressure gas
b) Low pressure liquid
c) High pressure gas
d) High pressure liquid
a) Low pressure gas
The refrigerant leaving the condensing coil is a:
a) Low pressure gas
b) Low pressure liquid
c) High pressure gas
d) High pressure liquid
d) High pressure liquid
The purpose of the evaporator is to:
a) Release heat from the refrigerant
b) Absorb the heat into the refrigerant
b) Absorb heat into the refrigerant
The purpose of the TX valve is to:
a) Heat the refrigerant
b) Raise the pressure of the refrigerant
c) Lower the pressure of the refrigerant
d) Keep the refrigerant pressure constant
c) Lower the pressure of the refrigerant
A direct-fired make-up air unit will:
a) Have a heat exchanger
b) Not have a heat exchanger
b) Not have a heat exchanger
Which or the following applications would have the evaporator and condenser coils in the same unit?
a) Residential furnace with air conditioning
b) Make-up air unit
c) Rooftop HVAC unit
d) Both A and D
c) Rooftop HVAC unit