HPSW and Cooling Systems Flashcards

1
Q

What is the HPSW operating pressure?

A

7 bar (100psi-120psi)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is fitted to prevent system over pressurisation?

A

Relief valves and 10% leak off valves maintain the pressure at 7 bar.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

State six uses of HPSW.

A

Firefighting - hydrants/sprays/centre feed hose reels
Pre Wetting system
Fitted Bilge and Salvage Eductors
Emergency Cooling to main propulsion gas turbines/diesel generators
Auxilliary Machinery cooling water system
Making of fresh water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Explain the flow of SW from the Sea to the Ringmain.

A

salt-water pump pulls through the sea cock then a strainer while discharging 10% through a discharge valve up through the riser then supplying the ringmain at 7 bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Explain the HPSW Ringmain.

A

The ringmain is a long multi-section of pipework that runs along 2 decks supplies multiple systems with salt-water throughout the ship such as the emergency cooling systems and pre wet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How are the HPSW pumps driven and where can they be operated from?

A

The are driven electrically and are operated both locally and remotely

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where will HPSW sprays be located?

A

Magazines
Paint lockers
Inflam store
Funnels

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Explain the Pre-Wet system.

A

The pre wet system when put to use protects the top deck of the ship from biological/chemical weapons and nuclear debris by coating it in water and preventing any substances from sticking to the deck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Explain the system configuration in DC State 1.

A

All the pumps are running
The DC State 1 Valves are shut
The HPSWM is divided (isolated) into zones

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Explain the system configuration in DC State 3.

A

One pump is running (one pump can supply the whole ship)
Other pumps are on stand-by and can be started if pressure drops
All the DC State valves are open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When may more pumps be introduced?

A

When the pressure drops below 7bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

State the machinery being cooled by the Main Propulsion cooling system.

A

Gas Turbine Cooling
Plumber block emergency cooling
Main Forced Lub system cooling
Controllable Pitch Propeller (CPP) cooling – if fitted

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

State the machinery being cooled by the Auxiliary cooling system.

A

Diesel Generators

Air Conditioning Plants

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When would a cross connection between port and starboard be used?

A

When one sides intake needs to be isolated to clean out a strainer or provide other maintenance without stopping the system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What temperature do white metal bearings melt at?

A

115 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What my happen to machinery if it is not correctly cooled?

A

could breakdown and seize, it could strip its bearings or it could catch fire from overheating

17
Q

Why is FW (Fresh Water) used in a cooling system?

A

Materials used in the equipment may be susceptible to Salt Water corrosion and may wear out exceptionally fast, The equipment or system cooled by the fresh water system could be seriously affected by Salt Water contamination.

18
Q

What definition of system is the FW/SW?

A

the SW system is a open loop system and the FW is a closed loop system

19
Q

When could the FW be Cross connected to the SW?

A

If the FRESH WATER PUMP fails, but this is only done in an emergency and the MEOs permission is required

20
Q

Whose permission would be needed?

A

MEO