What is the HPSW operating pressure?
7 bar (100psi-120psi)
What is fitted to prevent system over pressurisation?
Relief valves and 10% leak off valves maintain the pressure at 7 bar.
State six uses of HPSW.
Firefighting - hydrants/sprays/centre feed hose reels
Pre Wetting system
Fitted Bilge and Salvage Eductors
Emergency Cooling to main propulsion gas turbines/diesel generators
Auxilliary Machinery cooling water system
Making of fresh water
Explain the flow of SW from the Sea to the Ringmain.
salt-water pump pulls through the sea cock then a strainer while discharging 10% through a discharge valve up through the riser then supplying the ringmain at 7 bar
Explain the HPSW Ringmain.
The ringmain is a long multi-section of pipework that runs along 2 decks supplies multiple systems with salt-water throughout the ship such as the emergency cooling systems and pre wet
How are the HPSW pumps driven and where can they be operated from?
The are driven electrically and are operated both locally and remotely
Where will HPSW sprays be located?
Magazines
Paint lockers
Inflam store
Funnels
Explain the Pre-Wet system.
The pre wet system when put to use protects the top deck of the ship from biological/chemical weapons and nuclear debris by coating it in water and preventing any substances from sticking to the deck
Explain the system configuration in DC State 1.
All the pumps are running
The DC State 1 Valves are shut
The HPSWM is divided (isolated) into zones
Explain the system configuration in DC State 3.
One pump is running (one pump can supply the whole ship)
Other pumps are on stand-by and can be started if pressure drops
All the DC State valves are open
When may more pumps be introduced?
When the pressure drops below 7bar
State the machinery being cooled by the Main Propulsion cooling system.
Gas Turbine Cooling
Plumber block emergency cooling
Main Forced Lub system cooling
Controllable Pitch Propeller (CPP) cooling – if fitted
State the machinery being cooled by the Auxiliary cooling system.
Diesel Generators
Air Conditioning Plants
When would a cross connection between port and starboard be used?
When one sides intake needs to be isolated to clean out a strainer or provide other maintenance without stopping the system
What temperature do white metal bearings melt at?
115 degrees