High Rise Incidents Flashcards

1
Q

Incident Priorities

A

• Protection Of Life
_• Incident Stabilization Through Fire Control
ncident Priorities:
• Property / Environment Protection And Conservation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Tactical Priorities

A

• Investigation / Rescue / Fire Attack / Property Conservation / Environment
• Ensure Adequate Water Supply
• Gain Control Of Buildings Systems (Lobby Control), (HVAC)
Control of The Fire Floors Above and Below the Fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

First-In Company

Size Up

A

Location Of Fire By Address
Products Of Combustion
Numerical Floor Height And Type Of Occupancy Special Instructions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

First-In Company

Investigation / Initial Action, Rescue / Fire

A

• Call Elevator Cars Into Phase I
• Check Annunciator Panel For Fire Locations
• Ascertain Pertinent Information From Occupants
• Check Conditions On Fire Floor And Floors Above And Below The Fire
Check Conditions Two Floors Below Fire Floor For Staging
Communicate Location, Conditions, and needs to I.C.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

First-In Company

Pass Command to 2nd in Engine

A

• Annunciator Panel Information
• Elevator Status
• The Route Of Ascent Into The Building By Fire Attack Crews
(Include Stairwell Location And Identification)
• Any Other Pertinent Information

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

First-In Company

Water Supply

A

Two Engines, Two Engineers, 1st And 3rd Company Will Generally Handle
1st Engine should be from Primary Water Source, then another Engine will be Required to Pump to First-in Engine.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Secound-In Company

Command/Follow-Up

A

Establish Command Post Determine Adequacy Of Resources Follow Up Report
- Identify Incident
- Identify Command Post Location
- Order Additional Resources And State “Staging” Location–for Fire, Amb & other - Two Or More Divisions Order An Additional Command Frequency
Gain Control Of The Building Systems (HVAC, Elevators & Water Supply) Maintain Necessary Re-Stat / Sit Stat Records
Provide for ICS Positions as needed (Div / Grps)
Communicate Status Report (Situation, Progress, Needs, Every 30-45 min.)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Secound-In Company

Lobby Control Operations

A

Lobby Control Operations
Assign Lobby Control Manager
Maintain Control Of Building Systems (HVAC, Elevators & Water Supply) Check-In Arriving Personnel & Maintain Re-Stat Records
Recall Elevators - Phase I & II
Establish Communication with I.C. and Land Line with Dispatch
Establish Public Address to Reassure & give Direction to Building Occupants Direct Fire Fighter’s To Proper Stairwell for Ascent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Third In Company

A

Water Supply/ Manpower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Fourth In Company

Estsablish Base

A

Locate Base 200’ Away
Assign Base Manager
Initiate Diagonal Parking
Establish Communication With I.C. Check-In / Re-Stat Records

How well did you know this?
1
Not at all
2
3
4
5
Perfectly