High Rise Flashcards

1
Q

The purpose of the search and evacuation it to _______.

pg. 65

A

control occupants

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Changes in conditions regarding smoke, heat, or fire must be monitored and report through the ________________ supervisor to command.

pg. 65

A

Search and Evacuation supervisor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A search and evacuation branch or group should be activated if there are __________.

pg. 65

A

more than two floors above the fire that still contain building occupants.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The search and evacuation on post should be at least _____ floors above the highest fire floor & located _____ near the ______ stairwell.

pg. 65

A

two floors above the highest fire floor and located inside the floor, and near the evacution stairwell.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

At minimum stairwell support will need a firefighter postioned every _____ floors to effectively shuttle equipment.

pg. 66

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Personnel should anticipate no more than ____ to _____ minutes per air cylinder during firefighting operations.

pg. 66

A

15 to 20 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The EMS branch is responsible for managing _______.

A

all civilian patients.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The medical unit is responsible for the care and treatment of ______. Ideally the medical unit will be located ______.

pg. 66

A

fire department personnel. one floor below staging.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The _____ or ______ will normally serve as the initial planning section officer.

A

battalion aid or ems supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The logistics section is a ______ function.

pg. 67

A

command post

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Each fire station shall ensure that preplans exist for the high rise structures in their area. Where possible a copy shall be placed ______ at each building.

pg. 1

A

in the fire control room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A high rise building is defined as __________.

pg. 2

A

six or more stories or a buildingwhere the highest occupied story/floor is greater than 75 feet from the lowest level of fire department vehicle access.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In February 1976, the Virginia Uniform Statewide Building Code was modified to require a _______ in buildings having occupied floors located more than 75 ft. above the lowest level of fire department vehicle access.

pg. 2

A

fire control room.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Most are built using ____ construction.

pg. 2

A

fire resistive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The time needed to identify and confirm fire floor, proceed to that floor, locate the fire on the floor, and prepare to operate is known as _________.

pg. 2

A

reflex time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Modern high-rise buildings are of two basic designs: _____ and _______.

A

residential-center hallways, numerous interior compartments.

commercial -center-core construction on with circuit corridors around the core of the building.

17
Q

Typical fire suppression requirements for buildings with atriums include ____,_____,and _____.

pg. 4

A

full sprinkler protection, smoke exhaust systems, and smoke curtains.

18
Q

If the hallways are sectioned off by the use of fire doors, you will typically find ____ and _______ for each area or section.

pg. 5

A

a stairwell and standpipe.

19
Q

A class III standpipe system has a _____ inches in diameter and have _____ inch reducers.

pg. 6

A

2 1/2 and 1 1/12

20
Q
A