High Rise Flashcards
First two engines on an augmented high rise response
Attack
First truck in high rise ICS
Lobby
2nd truck in high rise ICS
Staging
3rd engine in high rise ICS
Base (engineer becomes water supply)
4th engine in high rise ICS
Search and rescue
5th engine in high rise ICS
Support
5th company in high rise ICS
Base
1st RA assignment
Medical Group (in staging)
2nd RA assignment
Medical (in lobby)
Where is staging located?
2 floors below the fire
How far away from the building is base?
200’
Who does lobby, base, and stairwell support report to?
Logistics Section Chief (if established)
Who does fire attack (division xx) and staging report to?
Operations Section Chief
Definition of a high rise
Building having floors used for human occupancy more than 75 feet above the lowest fire department accessD
Definition of mid rise
Building having floors for human occupancy more than 35 feet but less than 75 feet above lowest FD acess
Where does RIC/RIG stage?
in staging (2 floors below fire)
What to pump at if there is a stamped pressure?
No water flowing: 50 psi below stamped pressure
Water flowing: Stamped pressure and up to 50 psi over if crews request more pressure
How to tell if water is flowing through FDC?
Feather discharge gate and see if pressure drops
If pressure drops, water is flowing