Hemodynamic monitoring Flashcards

1
Q

Minimal Standard Monitors

A

1 .Electrocardiogram (HR and rhythm)

  1. Blood pressure
  2. Precordial stethoscope
  3. Pulse oximetry
  4. Oxygen analyzer
  5. End tidal carbon dioxide

document q5 min minimum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Minimal Standard - On Graphic Display

A
  1. Electrocardiogram
  2. Blood pressure
  3. Heart rate
  4. Ventilation status
  5. Oxygen saturation

continuous display

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

precordial sthetoscope

A

a stethoscope that is placed on the chest (just the bell part) that is attached to tubing with an ear piece on the other end

used for continuously listen to breath sounds and heart tones throughout the case.

You can quickly pick up on changes in patient condition (loss of breath sounds, loss of heart tones, etc).

used in peds 100% of the time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

esophageal sthetoscope

A

used for continuous assessment of a pt’s breath sounds and health sounds

placed inside of the ETT - pt has to be intubated

28-30 cm into the esophagus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

EKG

what is it? what it is not?

A

Recording of electrical activity of the heart

does NOT tell you about circulation

NOT a pulse rate monitor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

EKG - what do you use it for?

A
  1. – Detect arrhythmias
  2. – Monitor heart rate
  3. – Detect ischemia
  4. – Detect electrolyte changes
  5. – Monitor pacemaker function
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

5 Principle ECG Indicators of Acute Ischemia

A
  1. ST segment elevation , ≥1mm
  2. T wave inversion
  3. Development of Q waves
  4. ST segment depression, flat or downslope of ≥1mm
  5. Peaked T waves
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Lead I, AVL, V1-V4

A

Anterior wall ischemia (left coronary artery)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Lead V1-V4

A

Anterioseptal ischemia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Lead I, AVL, V5-V6

A

Lateral wall ischemia

(circumflex branch of left coronary artery)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Lead II, III, AVF

A

(Posterior)/ Inferior wall ischemia

(right coronary artery)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How far is an esophageal stethoscope inserted into the esophagus?

A

28-30cm.

This allows us to hear heart sounds and BS internally.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are precordial and esophageal stethoscopes useful for?

A

Continuous assessment of heart and breath sounds.

Very sensitive monitor for bronchospasm and changes in pediatric patients

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How often should we have a regular stethoscope available?

A

At all times

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What 4 general things are continually evaluated?

A

Oxygenation, ventilation, circulation, and temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Considerations in deciding what type of monitoring to use

A

1) Indication
2) Risk/benefit
3) Complications
4) Alternatives
5) Cost
6) Skill level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Types of hemodynamic monitoring used

A

EKG, BP (NIBP and IABP), CVP, PAP, PCWP, TEE, stethoscope

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What can the EKG tell you?

A
  1. Heart rate
  2. arrhythmias
  3. Ischemia
  4. electrolyte imbalances
  5. pacemaker function
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Aspects of the 3 Lead EKG

A

Electrodes used: RA, LA, LL

Leads: I, II, III

Number of views of the heart: 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Aspects of the 5 lead EKG

A

Electrodes used: RA, LA, RL, LL, chest

Leads: I, II III, AVL, AVR, AVF, V lead

Number of views of the heart: 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Value of the length and width of each EKG box

A

0.1mV and 0.04s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

How to calculate HR based on EKG lead

A

1500/# boxes between R waves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

How should the gain be set in order to accurately assess the ST segment?

A

At standardization (1mV signal gives a rise of 10mm).

This setting also fixes the ratio of the QRS complex to the ST segment size so that a 1mm change in the ST segment can be accurately assessed.

If the wrong gain setting is used, ST changes may be under or over-diagnosed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What filtering mode should the EKG be on for accurate ST assessment?

A

Diagnostic mode.

Filtering out the low end of frequency bandwith (which can happen on monitor mode) can lead to ST distortion (either elevation OR depression)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Posterior / inferior wall ischemia is seen in these leads and is due to a blockage in this artery
II, III, AVF Right coronary
26
Lateral wall ischemia is seen in these leadsand is due to a blockage in this artery
I, AVL, V5-6 Left circumflex coronary artery
27
Anterior wall ischemia is seen in these leadsand is due to a blockage in this artery
I, AVL, V1-4 Left coronary artery
28
Anterioseptal wall ischemia is seen in these leads and is due to a blockage in this artery
V1-4 Left anterior descending coronary artery
29
This part of BP correlates to the point of the most demand on the heart
SBP
30
The pulse pressure changes as you move from where to where
From the central arterial system to the periphery. The pulse pressure widens due to wave reflections in the vasculature.
31
These factors can cause a falsely high NIBP reading
1. Cuff too small 2. cuff below the level of the heart 3. loose cuff 4. arterial stiffness (HTN, PVD)
32
These factors can cause a falsely low NIBP reading
1. Cuff too large 2. cuff above the level of the heart 3. poor tissue perfusion 4. deflation is too rapid
33
Fals NIBP reading can also occur with
1. Cardiac dysrhythmia 2. tremors/shivering 3. improper cuff placement
34
This type of NIBP reading only gives you SBP
Palpation. It measures the return of arterial pulse during deflation. This is simple, inexpensive, and underestimates the SBP.
35
This NIBP reading only gives you SBP but measures it fairly reliably
Doppler. Measures it by a shift in frequency of sound waves that is reflected by RBCs moving through an artery.
36
This NIBP method estimates both SBP and DBP
Auscultation with a sphygmomanometer. Measures BP by auscultation Karotkoff sounds created by turbulent blood flow though the artery created by the mechanical deformation from the BP cuff. This method is unreliable in patients with HTN.
37
Changes in SBP correlate with changes in \_\_\_\_
Myocardial O2 demand.
38
Automated cuffs work by this mechanism
Oscillometry
39
Complications of NIBP measurement
1. Ulnar nerve damage 2. compartment syndrome 3. edema of the extremity 4. bruising / petechiae 5. pain 6. interference of IV flow 7. altered timing of IV drug administration
40
Indications for IABP monitoring (invasive)
1. Deliberate hypotension 2. Risk of rapid BP changes 3. Wide swings in BP intra-op 4. Rapid fluid shifts 5. Titration of vasoactive drugs 6. End organ disease 7. Repeated blood sampling 8. NIBP measurement failure
41
What test has to be done before radial a-line placement?
Allen's test
42
Rate that NS moves through the a-line system to prevent clot formation
1-3mL/hr
43
How can a-line dynamics and accuracy be improved?
1. Remove bubbles 2. calibrate at the level of the heart 3. minimize tube length 4. limit the number of stop-cocks 5. use non-compliant stiff tubing 6. make sure the mass of the fluid used is small
44
Where should the a-line be calibrated?
Supine patients- midaxillary line (right atrium) Sitting patients- level of the ear (circle of willis) because we are concerned about CBF
45
Rate of a-line upstroke tells you about
Contractility
46
Rate of a-line downstroke tells you about
SVR
49
Exaggerated variations in a-line tracing size with respirations indicates
Hypovolemia
50
The area under the a-line curve tells you
MAP
51
The dicrotic notch indicates the closure of this valve
Aortic valve
52
What happens to IABP readings as they move further into the periphery?
Distal pulse amplification! ## Footnote This causes **increased** SBP, **decreased** DBP, and increased pulse pressure. MAP remains **unchanged**. The dicrotic notch becomes less and less apparent and appears later in the tracing (takes longer for the pressure wave to reach the transducer).
53
Complications of IABP measurement
1. Nerve damage 2. hemorrhage/hematoma 3. retained guidewire 4. infection 5. thrombosis 6. air embolus 7. arterial aneurysm 8. vasospasm (usually self-limiting) 9. skin necrosis 10. loss of digits
54
Are fluids able to be given faster through a PIV or central line?
PIV
55
Indications for getting central access
1. Need more vascular access (unable to get enough PIVs) and need to rapidly give fluids - vascular access 2. give vasoactive meds 3. monitor CVP - measuring right heart filling pressure 4. assess fluid status/blood volume 5. sample venous blood 6. remove air emboli 7. pulmonary artery access 8. insertion of transvenous pacing leads
56
Why is the right IJ preferred to the left
1. It provides a more direct route to the heart 2. the dome of the lung is higher on the left 3. has the least aount of complications 4. left IJ takes a little turn - more challenging placement
57
Typical central venous catheter size
7 french 20cm
58
If anesthesia places a central line, is placement confirmed with an x-ray?
if placed in the IJ: * No, it is confirmed with blood aspiration from all 3 ports. X-ray is taken after surgery if decided to be kept in if placed in the subclavian: * YES
59
Where should the tip of the central line be located?
Tip in the SVC, just above the junction of the vena cavae and RA and parallel to the vessel walls. * bellow the inferior border of the clavicle at the level and above the 3rd rib * the T4/5 interspace or the level of the carina or R mainstem bronchus.
60
When is a central line contraindicated?
R atrial tumor Infection at site
61
Central line risks
usually d/t poor technique 1. Thrombo-embolism 2. air embolism 3. guidewire embolism 4. carotid puncture 5. hematoma 6. dysrhythmia - watch your EKG 7. pneumo/hemothorax 8. vascular damage 9. cardiac tamponade 10. infection
62
How is RVEDP measured with CVP tracing?
The a wave (end diastole) correlates with maximal filling of the right ventricle
63
What is the a wave?
Contraction of the right atrium, which results in increased RAP (since there is no pressure difference between the vena cava and the atrium)
64
The a wave follows this on the EKG
The p wave.
65
This CVP wave is the atrial kick (atrial contraction)
The a wave results in the filling of the right ventricle
66
What is the c wave a reflection of?
Isovolumetric contraction of the right ventricle, resulting in the *bulging back* of the tricuspid valve into the RA atrial pressure decreases after "a" wave d/t to relaxation - the little blip in pressure is related to the tricuspid valve bulging back
67
The c waves follows this waveform on the EKG
The QRS complex. The c wave occurs in early systole
68
The x descent occurs during
Mid-systole. The x descent follows the c wave. atrial pressure continues to decline cause atria relaxes (while the ventricle is contracting) aka "systolic collapse in atrial pressure
69
The v wave reflects what?
Venous return into the RA against a closed tricuspid valve return of blood into the right atrium from vena cava (encompasses a portion of the RV systole)
70
When does the V wave occur during the cardiac cycle and EKG?
At the end of systole with the tricuspid valve still closed, and it occurs just after the T wave.
71
What does the y descent reflect?
Passive ventricular filling after ventricular relaxation - tricuspid valve opens and blood flows from atrium into the ventricle The y descent reflects a fall in RAP due to this. This is referred to the "diastolic collapse in atrial pressure" - occurs in early diastole
72
What does CVP measure?
right sided pressures CVP measures the RAP (because it's right at the RA junction), which is a measure of right ventricle preload results from ebbs and flows of blood in the right atrium
73
Normal mean RA pressure in a spontaneously breathing patient is \_\_\_\_\_\_ and it rises about _______ during mechanical ventilation
1-7mmHg 3-5mmHg
84
Size of pulmonary artery catheters and number of lumels
1. 7-9 french 2. 110cm 3. 4 lumens * distal is for PAP * second is 30cm more proximal for CVP * third is for balloon * fourth is for the thermistor wires)
85
Indications for PAP monitoring
1. Unstable cardiac patients 2. LV dysfunction 3. Pulmonary HTN 4. ARDS/resp failure 5. Shock/sepsis 6. ARF 7. CAD 8. Valvular disease 9. Surgical procedures, such as cardiac, aortic, or OB 10. big cases that have lots of fluid shifts
86
Complications of pulmonary artery catheters
1. Arrhythmias (v-fib, RBBB, complete heart block)\*\*\* 2. PA rupture\*\*\*\* 3. Balloon rupture 4. Pulmonary infarction 5. Thromboembolism/air embolism 6. Pneumothorax 7. Catheter knotting 8. Damage to cardiac structures (valves) 9. Infection (endocarditis)
87
Relative contraindications to a PA catheter
WPW syndrome Complete LBBB
88
Distance from right IJ to various structures vena cava/RA junction, RA, RV, PA, PA wedge
SVC/RA junction- 15cm RA- 15-25cm RV- 25-35cm PA- 35-45 PA Wedge 45-50 If you go beyond these measurements and don't see the proper waveform, you may be coiling the catheter
89
1. Systolic upstroke 2. systolic peak pressure 3. systolic decline 4. dicrotic notch aortic valve closure) 5. diastolic runoff 6. end-diastolic pressure
90
match the waves with appropriate location
1. aorta 2. brachial artery 3. radial artery 4. femoral artery 5. dorsalis pedis
91
When might the a wave be larger than normal
Mitral/tricuspid stenosis
92
identify the waveform's location
93
When might the v wave be larger than normal?
Mitral/tricuspid insufficiency, causing blood to reflux into the atrium during systole. Remember that the v wave reflects atrial filling during late systole
94
Ways that we can measure CO
1. Thermodilution 2. continuous thermodilution 3. ultrasound 4. TEE 5. pulse contour 6. mixed venous oximetry
95
"a" waves may be lost with
a-fib ventricular pacing
96
Giant a waves ("Cannon" a waves) may be caused by
1. Junctional rhythms 2. complete HB 3. mitral stenosis 4. diastolic dysfunction 5. myocardial ischemia 6. ventricular hypertrophy
97
Large V waves may be caused by
Mitral/tricuspid regurgitation Acute increase in intravascular volume
98
7 things you can observe with TEE (cardiac parameters)
1. CO 2. Ventricular wall characteristics and motion 3. Valve structure and function 4. Measurement of EDV and ESV 5. Blood blow characteristics 6. Intracardiac masses 7. Intracardiac air
99
When is the use of TEE indicated?
1. Pericardial tamponade (for trauma) 2. Unusual causes of acute hypotension 3. PE 4. Aortic dissection 5. Myocardial ischemia 6. Valvular dysfunction ## Footnote Overall, if someone is still very unstable and unresponsive to our treatments, we can use TEE to get a better overall picture of our patients- checking to see what the actual structural problem might be
100
Complications of TEE
1. Esophageal trauma 2. Dysphagia 3. Hoarseness (upper airway issues) 4. Dysrhythmias Most complications are reported in awake patients
101
Invasive IABP measurement - what is it
Involves percutaneous insertion of catheter into an artery, which is then transduced to convert the generated pressure into an electrical signal to provide a waveform
102
Invasive IABP measurement - advantages
– Generates real-time beat to beat BP – Allows access for arterial blood samples – Measurement of CO/ CI/ SVR
103
how do you do an Allen's test?
occlude ulnar and radial artery release ulnar artery check for collateral flow
106
what do you use Pulmonary Artery Pressure Monitoring for?
Direct assessment of: 1. Intracardiac pressures (CVP, PAP, PCWP) 2. Estimate LV filling pressures 3. Assess LV function 4. CO 5. Mixed venous oxygen saturation 6. PVR and SVR measures the left side of the heart
108
PA catheter "a" wave (PCWP) - what is it?
contraction of the left atrium Normally it is a small deflection unless there is resistance in moving blood into the left ventricle as in mitral stenosis
109
PA catheter (PWCP) v wave - what is it?
blood enters the left atrium during late systole rapid rise in the left ventricular pressure in early systole, causing the mitral valve to bulge backward into the left atrium, so that the atrial pressure increases momentarily