HEARING CONSERVATION PROGRAM (HCP) RESPONSIBILITES,
CO
ESTABLISH A HCP
HEARING CONSERVATION PROGRAM (HCP) RESPONSIBILITES,
SAFETY OFFICER
LIAISON TO IH DEPT AND OCCUPATIONAL AUDIOLOGIST
WHO MAINTAINS RECORDS OF:
- NOISE HAZARDS AREAS/EQUIPMENT
- IH SURVEYS
SAFETY OFFICER
WHO ENSURES THE HCP PROGRAM IS EVALUATED ANNUALLY
SAFETY OFFICER
HEARING CONSERVATION PROGRAM (HCP) RESPONSIBILITES,
IH OFFICER
- PROPER CALIBRATION OF THE SOUND LEVEL METER
- ANNUALY CERTIFY AUDIO BOOTHS
HEARING CONSERVATION PROGRAM (HCP) RESPONSIBILITES,
DIVO
ENSURE NOISE HAZARDS LABELS PLACED
HEARING CONSERVATION PROGRAM (HCP) RESPONSIBILITES,
MEDICAL DEPT REP
- CONDUCTS TRAINING FOR ALL HANDS
- CONSULTS W/ IH SURVERY FOR HEARING PROTECTION TYPES
- PREFORM FIT TESTING
- MAINTAIN ROSTER OF HCP
WHO REPORTS PERSONNEL WITH PERMANENT THRESHOLD SHIFTS?
AND TO ?
WHAT INFO?
MEDICAL DEPT REP REPORTS THIS TO SAFETY OFFICER
- NAME
- RATE/RANK
- WORK CENTER
- TIME ON SHIP
HOW OFTEN MUST HCP TRAINING BE DONE?
- INTIAL, UPON CHECK IN (INDOC)
- ANNUAL
NAVMED 6260/2
HAZARDOUS NOISE DECAL
8X10
POSTED OUTSIDE DOORS/HATCHES LEADING TO HAZARDOUS NOISE AREA
NAVMED 6260/2A
HAZARDOUS NOISE LABEL
2X2
PLACED ON EQUIPMENT/TOOLS
WHAT TYPE OF NOISE ABATEMENT IS DONE FIRST
REDUCTION OF NOISE AT ITS SOURCE
WHEN SHOULD EQUIPMENT BE MODIFIED TO REDUCE NOISE?
DURING DESIGN, CONSTRUCTION, TESTING
WHAT ARE THE 3 TYPES OF HEARING TESTS?
- REFERENCE HEARING TEST
- MONITORING HEARING TEST
- TERMINATION HEARING TEST
DD 2215
REFERENCE AUDIOGRAM
DD 2216
MONITORING AUDIOGRAM
WHEN IS NO HEARING PROTECTION IS REQUIRED?
NOISE LEVELS LESS THAN OR EQUAL TO 84 dBA
WHEN IS SINGLE HEARING PROTECTION REQUIRED?
NOISE LEVELS EQUAL TO 85 OR GREATER, BUT LESS THAN 96 dBA
WHEN IS DOUBLE HEARING PROTECTION REQUIRED?
NOISE LEVELS EQUAL TO 96 dBA OR GREATER
WHO TAKES NOISE LEVEL MEASUREMENTS
IH OR OCCUPATIONAL AUDIOLOGIST
A RESURVEY SHOULD BE DONE HOW MANY DAYS AFTER SIGNIFICANT CHANGES/MODIFICATIONS
30 DAYS
HOW LONG ARE RECORDS OF NOISE MEASUREMENT KEPT?
AND BY WHO?
50 YEARS
BY THE MEASURING ACTIVITY
DOES THE MEPS AUDIOGRAM COUNT AS THE REFERENCE?
NO, MUST BE DONE ON ALL PERSONNEL ENTERING NAVAL SERVICE
WHAT IS A SIGNIFICANT THRESHOLD SHIFT
A CHANGE IN HEARING MORE THAN 10dB OR MORE AT 2000,3000,4000 Hz