HazMat Bull No. 5 Control of City Gas Flashcards

1
Q

Natural Gas is not poisonous- test show that concentrations of ____ natural gas mixed with air produces no ill effects?

A

25%.

HazMat Bull No. 5 page 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Natural gas is ___ than air?

A

Lighter.

HazMat Bull No. 5 page 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Natural gas when burning produces _______ heat?

A

High radiant.

HazMat Bull No. 5 page 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The ignition point of natural gas is ____ degrees to ____ degrees?

A

1100-1200.

HazMat Bull No. 5 page 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Natural gas emergencies can be classified into four basic situations?

A
  1. Gas escaping outside.
  2. Gas burning outside.
  3. Gas escaping inside.
  4. Gas burning inside.
    HazMat Bull No. 5 page 1
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

On a natural gas leak if manpower is available ________ in the immediate area to determine whether gas is getting into buildings?

A

Check structures.

HazMat Bull No. 5 page 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If natural gas is escaping inside a building, ventilate the area, starting where the gas concentration is the _______?

A

Strongest.

HazMat Bull No. 5 page 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Once a gas valve of any type has been turned off for any reason, _____ back to the on position?

A

Do not turn it.

HazMat Bull No. 5 page 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

In certain cases, where gas is supplied at low pressure, and two or more meters are used, or the distance between the point where the service pipe passes through the building wall and the gas meter exceeds _______, an additional stopcock is located in the service pipe between the point where it passes through the building wall and the gas meter?

A

20 feet.

HazMat Bull No. 5 page 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Residential installations of gas meters located on the outside building wall will normally have a service from the main underground to the base of the building wall and one stopcock on this service pipe just ahead of the meter and/or regulator. This stopcock may have the __________on it depending upon the use of the residence?

A

Pentagonal nut adapter.

HazMat Bull No. 5 page 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
  • Turn the stopcock so that the operating lug is ______ to the gas pipe. This stops the flow of gas in the pipe?
A

Crosswise.

HazMat Bull No. 5 page 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Use _______ to move the stopcock to the off position. Avoid sudden, excessive force that might break the pipe at the threaded connections?

A

Gradual pressure.

HazMat Bull No. 5 page 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

More than a _____ of a turn will allow gas to continue to flow?

A

1/4.

HazMat Bull No. 5 page 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The fire valve has a raised operating stem inside a _____ diameter pipe?

A

2-1/2”.

HazMat Bull No. 5 page 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The fire valve has a raised operating stem inside a 2-1/2” diameter pipe; which projects about ____ above grade?

A

12”.

HazMat Bull No. 5 page 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The fire valve has a raised operating stem inside a 2-1/2” diameter pipe; which projects about 12” above grade The 2-1/2” diameter pipe is closed on top by a ____sided threaded nut?

A

5.

HazMat Bull No. 5 page 3-4

17
Q

Remove the fire valve cap with a fire plug wrench by turning it _______. If it does not move readily, tap around the edge of the cap while applying pressure in a counter clockwise direction. After removing the cap use a fire plug wrench to turn the operating head 1/4 turn clockwise?

A

Counter clockwise.

HazMat Bull No. 5 page 4

18
Q

Remove the fire valve cap with a fire plug wrench by turning it counter clockwise. If it does not move readily, ________. After removing the cap use a fire plug wrench to turn the operating head 1/4 turn clockwise?

A

Tap around the edge of the cap while applying pressure in a counter clockwise direction.
HazMat Bull No. 5 page 4

19
Q

On a curb stopcock remove the stopcock box cover and turn the valve _______ with a gas stopcock wrench (Tee Handle)?

A

1/4 turn either way

HazMat Bull No. 5 page 4

20
Q

On a curb gate valve remove the valve box top and turn the ___________clockwise until the valve resists further turning; six to twenty turns depending on the size of the valve. This type of shutoff is sometimes used in lieu of a fire valve with written approval of the D.C. Fire Marshal?

A

Hand wheel or 2” square operating head.

HazMat Bull No. 5 page 4

21
Q

On a curb gate valve remove the valve box top and turn the hand wheel or 2” square operating head clockwise until ____________ depending on the size of the valve. This type of shutoff is sometimes used in lieu of a fire valve with written approval of the D.C. Fire Marshal?

A

The valve resists further turning; six to twenty turns.

HazMat Bull No. 5 page 4

22
Q

On a curb gate valve remove the valve box top and turn the hand wheel or 2” square operating head clockwise until the valve resists further turning; six to twenty turns depending on the size of the valve. This type of shutoff is sometimes used in lieu of a fire valve with written approval of ________?

A

The D.C. Fire Marshal.

HazMat Bull No. 5 page 4

23
Q

Gas valves located in ______should not be operated. These control the gas flow in gas mains and the operation of these valves by other than Gas Company personnel could create a very serious hazard?

A

Streets and alleys.

HazMat Bull No. 5 page 4

24
Q

A red tag reading ______ must be attached to any gas valve or gas control operated by a firefighter, or Gas Company personnel. This is the signal to other companies responding that the gas is off and also that it is not to be turned on by anyone other than Gas Company personnel?

A

“Gas Off”

HazMat Bull No. 5 page 5

25
Q

A red tag reading “GAS OFF” must be attached to any gas valve or gas control operated by a firefighter, or Gas Company personnel. This is the signal to other companies responding that the gas is off and also that it is not to be turned on by anyone other than _____?

A

Gas Company personnel.

HazMat Bull No. 5 page 5

26
Q

Natural gas mains in the District are made from?

A

Cast Iron, Steel, Wrapped/Coated Steel, Plastic Piping.

HazMat Bull No. 5 page 5

27
Q

Natural gas service lines in the District are made from?

A

Steel, Wrapped/Coated, Copper, Plastic Piping.

HazMat Bull No. 5 page 5

28
Q

Natural gas system pressures for Transmission lines are?

A

60 to 300 psi.

HazMat Bull No. 5 page 5

29
Q

Natural gas system pressures for distribution lines are?

A

1/5 to 60 psi.

HazMat Bull No. 5 page 5

30
Q

Natural gas system pressures for low pressure lines are?

A

1/5 to 1/4 psi.

HazMat Bull No. 5 page 5

31
Q

Washington Gas Company operates a natural gas fueling station located at?

A

1240 12th Street S.E.

HazMat Bull No. 5 page 5

32
Q

At natural gas fueling stations Fill pressure at the outlet of the fueling nozzle is approximately _____, with emergency shutoffs located at different locations for each application

A

3000 psi.

HazMat Bull No. 5 page 5

33
Q

Gas flowing through an open, damaged, or ruptured plastic gas line will cause a build-up of _______ on the surface of the plastic that is exposed to the atmosphere?

A

Static electricity.

HazMat Bull No. 5 page 5