HazMat 5-19 Flashcards

1
Q

IC shall special call a CPC Unit or HMTU as a FAST unit to the scene if _ for a Haz Mat emergency

A

More than two (3/more) Entry teams are EXPECTED to be put to work Ch 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Each employee in an excavation shall be protected from cave-ins by shoring except when:
Excavations are _ or excavations are less than _’

A

Excavations are made entirely in stable rock; or
Excavations are less than 5’ in depth and examinations of the ground by a competent person provides no indication of a potential cave-in Ch 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A stairway, ladder, ramp, or other safe means of egress shall be located in trench excavations that are _’ or more in depth

A

4’ or more in depth so as to require no more than 25’ of lateral travel for employees
Ch 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Chemical Suicide Primary Hazardous threat to 1st responders

A

Inhalation (Primary)

Ch 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Chemical Suicide in car victim may be which color?

Which chemical odor?

A
Red in color (similar to CO poisoning);
Hydrogen Sulfide (rotten eggs) Ch 11
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Code given for Chemical Suicide

A

10-80 Code 1. Ensure NYPD response (Crime Scene)

Ch 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Chemical Suicide use meters to monitor _

A

Oxygen levels, flammable vapor concentrations, and presence of hydrogen sulfide, hydrogen cyanide, or other chemicals. Ch 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hydrogen Sulfide Odor and Flammable Range

A

Rotten Eggs; 4-44%

Ch 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

CO odor and Flammable Range

A

Odorless; 12.5-74%

Ch 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Hydrogen Cyanide Odor and flammable range

A

Bitter Almond like; 5.6-40%

Ch 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Phosphine Gas Odor and Flammable range

A

Fish or Garlic like odor;

1.8%-? Ch 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Technical Decon Task Force consists of _

A

SOC Support Ladder, its associated Decon Engine and Admin BC

Ch 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Each Tech Decon Task Force will be identified by _

A

ID by the Battalion from which it was called. Ex Battalion 26 designated as Technical Decon Task Force 26
Ch 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

All communications between Task Force and IC will be accomplished through _

A

Task Force Leader. Upon arrival Task Force Leader shall report to FD IC or Operations Chief, then obtain briefing from Haz Mat Director/Group Supervisor Ch 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

USPS Bio Detection is considered (Single/Unified)

A

Unified w/FD primarily operating w/in Haz Mat Branch and Medical Branch. Ch 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

FD Staging Area for Bio Detection Systems in USPS

A

Established as per Individual Facility Plan. Staging Area Manager shall be designated Ch 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Code transmitted for Bio Detection System in USPS

A

10-80 once confirmed. All BDS alarms treated as Haz Mat incidents. Units shall NOT enter unless life hazard. Ch 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

BDS who is responsible for Primary and Secondary searches in USPS

A

USPS responsible for accounting for all employees, visitors, and customers. Ch 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

BDS who is responsible for Decon in USPS

A

FD Units responsible for Decon of Group 2 and Group 3 patients. Group 1 evacuate to separate SRA w/no decon req’d. Ch 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Code given for Suspicious package, envelope, or powder ex. Anthrax

A

10-80 specifying suspected anthrax. If PD NOT on scene immediately request response. Ch 15

21
Q

CPC Off Haz Mat incident correct
A. Recommend to IC entry point into Hot Zone
B. Don CPC suit because entry team was not in line of site
C. Est 2nd HT Channel for CPC members
D. Est and maintain written log of “On Air” times

A

A B C D

22
Q

The IC shall special call a CPC Unit or HMTU as a FAST Unit if
A. Two entry teams are working
B. More than two entry teams are working
C. More than two entry teams are expected to be put to work
D. Two entry teams are expected to be put to work

A

C

23
Q

Large Haz Mat incident w/multiple victims (3/more) proper sequence to remove patients
A. Ambulatory victims directed to CCP, Unconscious victims that respond to NST removed to 2nd CCP, Black tagged non-responsive victims removed last
B. Black tagged non-responsive removed to CCP, Ambulatory victims directed to a CCP, Unconscious victims respond to NST removed to 2nd CCP
C. Unconscious victims that respond to NST removed to CCP, Black tagged non-responsive removed to 2nd CCP, Ambulatory victims directed to CCP

A

A

24
Q

Incorrect for Decon
A. If pts and responders wearing CPC both require Tech Decon, 1 Tech Decon Task Force can perform both tasks
B. Single decon corridor can be used for different types of decon (CPC, ambulatory, non-ambulatory)
C. If FD members are contaminated w/asbestos. they may have to stand in a SRA prior to decon
D. Water supply and fog line must be est for emergency decon if need arises

A

B Separate decon corridor for each

25
Q
Tech Decon Task Forces will be ID by _ number
A. Engine 
B. Ladder
C. Battalion
D. Incident
A

C

26
Q

Correct for Tech Decon Task Force
A. Chief of Battalion 29 is the Leader of your Task Force
B. LT of Task Force may call IC on HT Cmd Ch 1 to report that decon corridor has been est
C. SCBA must be used while performing decon activities
D. This Task Force is expected to perform mass gross decon while using Aquastream or Turbomaster fog noz

A

A
B All comm between Task Force and IC will be accomplished via Task Force Leader. Cmd Ch is Ch 2
C IC may deem APR or PAPRs safe to use
D This unit performs Tech Decon NOT Mass Gross Decon w/Aquastream or Turbomaster

27
Q

Chemical attack in subway that produces numerous ambulatory and non-ambulatory patients, special call at least _ Tech Decon Task Forces Immediately
A. 1 B. 2 C. 3 D. 4

A

D One for ambulatory patient decon, One for Responder decon, and Two to perform non-ambulatory patient decon

28
Q

Incorrect for BDS activation at Postal Service
A. Postal Service is responsible to conduct primary and secondary searches if necessary
B. FD will be IC at all USPS BDS activations
C. FD mission is to triage, treat, and decon
D. 1st FD units shall not enter facility unless life hazard that needs to be addressed immediately

A

B Unified Command Ops

29
Q
BDS alarm verified by USPS Liaison 1st units should transmit 10-
A. 80 Code 1 
B. 80 Code 2 
C. 80 No Code 
D. None of the above
A

C

30
Q

Patients exposed to unknown substance incorrect:
A: Proper Personal Protective Equipment (PPE) shall be worn at all times when dealing with patients.
B: When the patient reports that they were contaminated and they have visible powder or other substance on their skin or clothing, ask the patient to remove their outer clothing, if possible, and provide the patient with a disposable garment or sheet.
C: When req’d, bag the pt’s clothing in a clear, plastic bag and leave with a competent authority on scene.
D: Assess, treat and transport the patient as appropriate. Only patients who are deemed Critical should receive Emergency Decontamination and be treated and transported immediately.

A

D. Assess, treat and transport the patient as appropriate. Patients who are Critical or Unstable should receive Emergency Decontamination and be treated and transported immediately.
HM 16 2.2

31
Q

Male contaminated w/visible white powder from a suspicious package w/difficulty breathing and unstable. Choose incorrect
A. Have pt remove outer clothing and provide pt w/disposable garment or sheet
B. Bag pts clothing in a clear plastic bag and give it to EMS for transport w/pt
C. Provide emergency decon and treat pt immediately
D. Insure members wash their hands, face, and any exposed skin upon completion of this assignment

A

B Bag the patient’s clothing in a clear plastic bag and leave with a competent authority on scene.

32
Q

BDS in USPS Mail Facility correct
A. Initial responding units should meet USPS personnel at designated ICP
B. Transmit 10-80 Code 3 for confirmed BDS activation
C. Prior to entry for life, an Emergency Decon area shall be est and BU team designated
D. Add’l units above initial alarm assignment shall respond to pre-designated FD Emergency Response Meeting Point

A

C
A Initial Response Meeting Point will be est as per Individual Facility Plan. Initial responding units will meet USPS personnel at this location to confirm the BDS Alert
B Transmit a 10-80 for a confirmed BDS activation.
D Any add’l units above the initial alarm assignment shall proceed to the pre-designated FD Staging Area (see USPS Individual Facility Plan).

33
Q

Single most important action associated w/Decon
A. Our ability to deliver large volumes of water quickly
B. Have all exposed people immediately removed from area of release to an area of safe refuge
C. Rapid physical removal of material from victims
D. Our ability to provide emergency high pressure streams supplying low vol of water

A

C

34
Q

Chemical suicides w/chemicals such as sulfides, acids, liq nitrogen, or hydrogen cyanide create a toxic area. Primary hazard to responders
A. Skin absorption or caustic acid contamination
B. Flammability
C. Inhalation
D. Blood borne pathogens

A

C

35
Q

Hydrogen sulfide gas will have _ odor, carbon monoxide will have _ odor, Hydrogen cyanide gas will have _ odor, and phosphine gas will have _ odor
A. Odorless/rotten eggs/bitter almond/fish or garlic
B. Fish or garlic/rotten eggs/bitter almond/odorless
C. Rotten eggs/odorless/bitter almond/fish or garlic
D. Bitter almond/fish or garlic/odorless/rotten eggs

A

C

36
Q

Chemical suicide correct
A. 1st Lad donned full PPE and wore SCBAs. Vented occupancy after entering and used meters to monitor O2 levels
B. 1st Eng transmitted 10-80 Code 3 after receiving confirmation that it was a chemical suicide incident and also ensured response of PD
C. 1st Eng stretched and charged HL and attached a fog noz which was used primarily for vapor dispersal. Pt care was provided according to CFR protocol
D. Hazmat Eng contained product, recapped any virgin product, and contained the mixture. Crime scene security was maintained until arrival of PD

A

D
A Vent prior to entering
B. 10-80 Code 1 Ensure the response of the NYPD
C Primarily for decon

37
Q

Incorrect duties of the CPC Unit Officer?
A: On arrival at a Haz-Mat incident the CPC Unit Officer shall report to the Incident Commander for a briefing.
B: The first arriving CPC Unit Officer will recommend to the IC the ENTRY POINT into the Hot Zone (based on their training, initial briefing and size-up).
C: IC will establish the CPC Unit Assembly Area remote from the entry point.
D: CPC Unit entries into a contaminated area require a coordinated team effort by at least five (5) CPC trained members: Entry (2), Backup (2), and Decon (1), under the proper supervision.

A

C. The CPC Unit Officer will establish the CPC Unit Assembly Area adjacent to the entry point.
HM 5 4.1, 5.1

38
Q

Where would add’l units above the initial alarm assignment respond to for a BDS activation?
A. Initial Emergency Response Meeting Point
B. Incident Command Post
C. Unified Command Post
D. Fire Dept Staging Area

A

D

39
Q

Which scenario would members NOT enter w/Bunker Gear not enter USPS BDS alarm activation (2)
A. Life threatening medical emergency
B. Life threatening fire
C. To treat a Postal Worker’s broken ankle, which was incurred while trying to proceed to SRA
D. To perform Decon of Group 2 and 3 patients

A

C D (only enter for life threatening scenario or fire)

40
Q

BDS alarm at USPS incorrect
A. ICP will be est at the pre-designated location
B. Unified Ops Post will be est based on Individual Facility Plan
C. FDNY Staging Area will be est based on Individual Facility Plan and a Staging Area Manager designated
D. Initial responding units should meet USPS personnel at pre-designated ICP to confirm BDS alert

A

D Initial Units will meet at Initial Emergency Response Meeting Point est at pre-designated location

41
Q

USPS BDS correct for 1st BC
A. Report to ICP
B. TAC U Channel should be est
C. FD units responsible for Decon of Postal Workers Groups 1, 2, and 3
D. Only Haz Mat Technicians in proper PPE may enter for Immediate Life safety issues

A

D
A 1st BC Establish or report to the Unified Operations Post as per the Individual Facility Plan. Staff Chief shall proceed to the Incident Command Post
B Establish a Command Channel
C FDNY units will be responsible for decontamination of Group 2 and 3 patients

42
Q

Regarding need to Decon patients or FD personnel at a suspicious package where there is suspected powder/anthrax, the decision will be made by IC in consult with _
A. NYPD IC
B. Haz Mat Battalion and EMS Haz Tac Officer
C. Citywide Tour Commander
D. Haz Mat Battalion

A

B

43
Q

Bunker gear removed for decon due to synthetic opioids, who determines method of decon
A. Haz Mat 1
B. Safety Battalion
C. Decon Support Unit w/Haz Mat Battalion
D. Safety Battalion in consult w/Haz Mat Battalion

A

C

44
Q

Lithium Ion Energy Storage Systems (ESS) incorrect
A. ESS that support utility electrical grid should not be shut down without consulting the Con Ed White Hat Representative
B. ESS that provide back up for critical infrastructure as an Uninterruptible Power Supply (UPS), should not be shut down without consulting a bldg engineer
C. Lithium ion battery fires may be deep seated, and may not be picked up by TIC
D. ESS involved in fire may re-ignite for a period of up to 60 minutes after final extinguishment seems to have been accomplished

A

D Li-ion-ESS may re-ignite hours to days after being involved in a fire

45
Q

ESS containers w/NO Smoke or Fire showing correct
A. Est Initial Danger Zone with a 40’ radius from any container
B. Est an Initial Danger Zone of 100’ from any container exhaust fan. Exhaust fans will usually be located on a container on same side as where FD Connection (FDC) is located
C. Stretch and charge a supply line to FDC. If FDC is closer than 50’ from nearest container, personnel may only enter this 50’ area w/approval of IC
D. Transmit 10-80 Code 1 to insure response of Haz Mat 1, HMTU and Haz Mat Battalion

A

D
A Initial Danger Zone
Minimum of 50 ft radius from container(s)/cabinet(s)
B Min of 100’ from container/cabinet exhaust fan opening (usually located on the container’s/cabinet’s side opposite FDC). Cabinets may not have exhaust systems
C If there is no rise in temperature of the battery or module, comply with the following: DO NOT charge the FDC water extinguishing system. DO NOT shut down ESS

46
Q

Rising temperature in battery modules incorrect
A. Water supply lines to FDC should be charged
B. ESS should be shut down under guidance of Con Ed White Hat
C. An exhaust fan override switch will be located at FDC
D. Exhaust fans should be operated before charging water extinguishing system

A

D

47
Q

Smoke showing from Cabinet ESS correct
A. Danger zone must be est- at least 50’ radius from containers/cabinets and 100’ from any possible exhaust fans
B. Cabinets will always have exhaust fans
C. ESTOP at FDC must be shut, but only Haz Mat Units are permitted to shut down ESS under guidance of Subject Matter Expert SME
D. Exterior HLs may be used to cool adj containers/cabinets. Use a wide fog (30 degrees or greater) from a close approach to cool uninvolved, adj containers/cabinets
E. Transmit 10-80 Code 2 for Haz Mat response

A

A
B Cabinets may not have exhaust systems
C 1st Alarm Units Shut down the ESS (ESTOP) at FDC or inside the electrical room if ESS is supplying a bldg
D Use narrow fog or straight stream application and maximum reach of streams if possible
E 10-80 Code 1

48
Q

After fire is controlled in Cabinet ESS, correct
A. SME are req’d to be on scene within 3 hours
B. FD personnel may open container/cabinet doors to vent, make entry for search, only after consulting w/SME
C. FD personnel may conduct overhaul operations only after consulting w/SME
D. IC should transfer responsibility to SME for decommissioning the Fire Watch est by DC

A

D
A w/in 2 hours
B FDNY PERSONNEL SHALL NOT ENTER ANY CONTAINER
C NO OVERHAULING SHALL BE PERFORMED ON ANY ESS

49
Q

SSL incorrect
A: Fully equipped B/U rescuer shall remain on stand-by in the event the primary (entry) rescuer is injured, overcome, or needs assistance in escaping the space.
B: SSL FF’s shall not be permitted to attempt any entry that would require the rescuer to leave the direct line of sight of the back-up rescuer.
C: SSLs shall only attempt an entry when all necessary precautions to safeguard the rescuer are taken, specifically, a suitable high point anchor shall be positioned to allow a retrieval system to be placed for immediate retrieval of the rescuers.
D: Air monitoring must take place which determines whether atmospheric hazards are present, and suitable steps must be taken to remove hazards or otherwise protect rescuers from their effects (e.g., use of the SCBA for asphyxiation hazard).

A

B. SOC Support Ladder Companies shall not be permitted to attempt any entry that would require the rescuer to leave the direct line of sight of the OFFICER supervising entry at the entrance to the space.
HM ch 10 7.2