Hazard Control And Loss Prevention Flashcards
What is the most important practice in storing chemicals? 1 ventilation 2 fire protection 3 grounding 4 segregation
4 segregation
When a firefighter must enter a burning building containing urethane insulation, which breathing apparatus would you recommend?
1 positive pressure SCBA
2 hose mask
3 oxygen mask
4 organic vapor chemical filter respirator
1 positive pressure SCBA
What type of sprinkler system is charged with water at all times? 1 wet pipe 2 dry pipe 3 pre-action 4 deluge
1 wet pipe
What type of sprinkler system is use where water damage is a concern? 1 wet pipe 2 dry pipe 3 pre-action 4 deluge
3 pre-action
What type of sprinkler system is used in explosive areas were all sprinkler heads are open? 1 wet pipe 2 dry pipe 3 pre-action 4 deluge
4 deluge
What type of sprinkler system would be most appropriate were freezing of the pipes is a concern? 1 wet pipe 2 dry pipe 3 pre-action 4 deluge
2 dry pipe
What is the acronym for colors of sprinkler heads?
UWBRGO
Under water boys regret growing old
An uncolored sprinkler head is suitable for use in which temperature range?
- 135-165 F. Ordinary
- 175-225 F. Intermediate
- 230-300 F. High
- 325-375 F. Extra high
- 135-165 f
Temperature classification ordinary
fusible link uncolored
frangible bulb orange or red
in colored sprinkler heads recite the chart
Temp range /temp class /fusible link frangible bulb
- 135-165 F. /Ordinary. /uncolored orange or red
- 175-225 F. /Intermediate /white yellow or green
- 230-300 F. /High /blue. Blue
- 325-375 F. /Extra high. /red. purple
The purpose of a horizontal exit above the ground floor is:
1 so a ramp can be used instead of stairs
2 to allow more time for use of vertical exits
3 to provide safe refuge while stairs in use
4 to escape the fire area into an area of refuge
4 to escape the fire area into an area of refuge
The highest protected type of stair enclosure recommended by NFPA 101 is:
- a smoke proof stairwell
- escape stairs
- elevator
- rope ladder
- a smoke proof stairwell
What is the minimum rating of a wall separating fuel and oxygen cylinders?
- 15 minutes
- 30 minutes
- 45 minutes
- 60 minutes
- 30 minutes
What is pyrolysis?
Decomposition of a material caused by heat
What is a detonation
sudden and violent release of mechanical chemical or nuclear energy from a confined space which creates a shockwave the travels at supersonic speeds
What is an explosion?
release of mechanical chemical or nuclear energy in a sudden and often violent manner with the generation of high temperature and usually with a release of gases
What is deflagration
Rapidly moving fire but slower than the speed of sound
What is pyrolysis?
Decomposition of the material caused by heat
Which organization regulates the storage, maintenance and fueling of forklift trucks
- OSHA
- ASSE
- NEC
- local fire department
- OSHA