Garden Apartment Flashcards

1
Q

Smoke showing from more than one stair well is an indication of what?

A

Basement/terrace level fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

what has proven to be one of the very most effective means to protect lives and property

A

Rapid fire extinguishment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Garden apartment buildings made of ordinary construction do not exceed how many stories and feet?

A

Four stories or 50 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When encountering a rain roof with fire under the flat roof but not yet impinged on the pitch roof what void space would it be in?

A

Cockloft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Balconies in garden apartments are of two general types

A

Extended and recessed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Soffit vents allow fire issuing from windows to extend where?

A

Attic area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Smoke issuing from the band board area of an exterior wall may indicate what?

A

That the fire has breached the truss floor space

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Each level of the garden apartment may contain how many apartments

A

between one and four

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When on a roof of a garden apartment, how can you tell where to cut a hole over the stair well?

A

look for the sidewalk and cut in line with that

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

what type of load is an HVAC unit

A

Concentrated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is a collapse hazard concern to firefighters in regards to egress when the fire has taken possession of the attic space

A

HVAC units positioned over the stair well

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The first due truck companies should take a position at the most strategic position to accomplish these 3 things

A

Access to the roof, rapid placement of ladders, entry into the structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The first due truck to position on what side of the building

A

Fire side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Many garden apartment buildings do not have windows on bravo and delta

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Lightwood frame construction is subject to early failure and has two distinct factors

A

presence of lightweight trusses, fire entering void spaces

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If the second due truck has no access to side Charlie it may require parking the vehicle where?

A

Parking at either end of the structure

17
Q

when entering from a common stairwell, which two quadrants would you begin a left hand search for the quickest window escape if necessary

A

Alpha, Charlie

18
Q

Typically how many feet deep are garden apartments?

A

50 feet

19
Q

1x3in boards typically cover the floor joist at what degree angle?

A

30 to 45 degree angle

20
Q

Floor joist are usually spaced how far apart

A

16in