Fuel Emergency Procedures Flashcards
1
Q
1 or 2 Fuel Filter Bypass
- or -
1 or 2 Fuel Press Caution
A
1) Fuel selector lever (affected engine)- XFD (DIR if currently in XFD)
2
Q
1 and 2 Fuel Filter Bypass
- or -
1 and 2 Fuel Press Cautions
1 W, 1 N
A
1) Land ASAP
2) APU Emergency Start procedure- Perform
Warning- Be prepared for dual- engine failure. Recommended airspeed is 80 KIAS to minimize Nr droop should dual-engine failure occur.
Note- Consideration should be given to performing applicable steps of the Immediate Landing/Ditching emergency procedure.