Fresh Water Generator Flashcards
1
Q
How to Start Fresh Water Generator?
A
- Open the Ejector Overboard Valve.
- Open Sea water inlet and outlet valve to the Ejector Pump
- Condenser Inlet & Outlet Valves
- Start the Ejector Pump
- Open feed water line (pre-heating)
- Open JW Outlet and Inlet valve (slowly)
- Open valve to distillate Pump and Start
- Wait for the PPM then press auto
2
Q
How to Stop FWG?
A
- Close dosing pump & salinometer
- Stop the flow of heating (JW) into the evaporator
- Stop Distillate Pump
- Once cooldown stop the ejector pump
- Close feed water valve
- Close the condenser inlet and outlet valve
- Close the ejector pump inlet and outlet valve
- Open the vacuum break
- Close ejector pump overboard valve