FRCS Flashcards
1
Q
Abort engine start by moving the condition lever to cut off feather and blow engine for ten seconds if
A
TOT does not rise within 3 seconds
TOT at 927c for 1 second
TOT between 810c and 927c for more than 10 seconds
Propellor does not then by 25% N1
2
Q
Shutdown engine by condition lever cut off feather if:
A
Oil Lo Press caption is not out by 60% N1
Propeller unfeathered by 60% N1
3
Q
What do you do if you see fumes during a blow or start before the condition lever is moved forward
A
Do not continue to blow or start. Ensure condition lever is cut off feather and conduct a motoring run
Condition lever - cut off feather Power lever - flight idle Batt or external power - on Fuel pump - on, f press out Start switch - blow and hold until TOT <150c Start switch - off Batt or external power - as required
4
Q
If TOT above 150c before starting the engine
A
Blow engine until TOT below 150 then wait for N1 to decay to between 1-4%