Forced-air furnaces w/s Flashcards
If the venting on a high efficiency furnace runs through unheated spaces, what must be done?
a) it must be insulated
b) it must be protected from damage
c) it must increased
a)
How would an installer determine the existing ductwork is adequately sized for the new high efficiency furnace?
a) complete a heat loss calculation
b) check the blower motor amp draw
c) perform an external static pressure test
c)
If an HRV is used in conjunction with a furnace, where is the HRVs warm air supply connected to the furnace system?
a) on the return air ducting but at least 3m from furnace
b) on supply air ducting but at least 3m from furnace
c) on the return air duct but no more than 3m from furnace
a)
If a furnace has air-conditioning added, where does the cased coil go?
a) downstream of the burner and downstream of the blower
b) upstream of the burner and upstream of the blower
c) downstream of the burner but upstream of the blower
a)
In what position can condensing furnaces be installed?
a) up or horizontal left only
b) up or horizontal left and right
c) up, down, horizontal left and right
d) only positions approved by the manufacturer
d)
What is the AFUE rating of a high-efficiency condensing furnace?
a) 83% or greater
b) greater than 83%
c) 90% or greater
c)
Which category of furnace is a high efficiency appliance?
a) category 1
b) category 2
c) category 3
d) category 4
d)
What type of furnaces use an inducer fan?
a) mid efficiency only
b) high efficiency only
c) mid efficiency, high efficiency
c)
Why is condensate considered corrosive?
a) it has low ph and low acidity
b) it has high ph and low acidity
c) high ph and high acidity
d) low ph and high acidity
d)
What is the draft pressure in the vent from a condensing furnace?
a) neutral
b) positive
c) negative
d) positive or negative depending on input
b)
How are type BH vents sized?
a) using furnace manufacturers literature
b) using vent pipe manufacturers literature
c) vent sizing tables
a)
When upgrading to a high efficiency furnace from a low efficiency model how is the appliance input decided?
a) complete a heat loss calculation
b) replace old trance with the same input
c) choose model that has the size size supply air plenum
a)
Can the vent from a condensing appliance be connected to the B-vent of the appliance it replaces?
a) no, a new vent needs to be installed
b) yes, if the existing vent is the correct size
c) yes, if the existing b vent is a side wall termination
a)
How is the bent piping graded for sidewall installation?
a) perfectly horizontal
b) toward the appliance
c) away from the appliance
d) to a low point
b)
Must a defective heat exchanger in a dwelling unit be replaced immediately?
a) yes
b) no, it can be temporarily repaired
c) no, it can be permanently repaired
d) no, only if CO level is above the maximum acceptable for the appliance
a) yes