A strainer is required by NFPA 1901 to protect the concentrate pump from debris that may be in the tank. The concentrate strainer should be cleaned on a ___.
regular basis
To clean the strainer, remove the large nut located on the bottom of the “Y” strainer. Remove the element and wash with ____.
fresh water
If little or no concentrate is being injected while foam pump is operating, check for a ___.
clogged strainer
Monthly :
Inspect ___, hoses, flow meters, and connections for tightness, corrosion, leaks and/or damage.
wiring
Monthly :
Remove and clean the foam strainer screen. ___ as required.
Flush
Monthly :
Check foam pump gear case oil level and refill as necessary with _____
SAE 30 weight non-detergent oil.
Annually: ____ the pump oil and refill pump crankcase with SAE 30 weight non-detergent oil. Check for concentrate or water in the drain oil.