foam Flashcards

1
Q

gpm when flowing elkhart?

A

95

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

gpm when flowing angus?

A

95

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

pump what pressure to the elkhart?

A

200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

pump what pressure to the angus?

A

150

60-150 med expansion

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

max 1 3/4 hose after eductor

elkhart and Angus

A

300’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

max 1 1/2 hose after eductor ?

angus and elkhart

A

150’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Foam ade 2000

what percent for class A

A

.10-.50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Foam Ade 2000

cars truck equipment

A

.50-1.0%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

non polar solvent

example gasoline

A

3%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

polar solvents

example alcahol ethanol methanol

A

6%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

class A foam proportioned at

A

.3-.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

class b foam proportioned at

A

minimum 1%

often 3%-6%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

(1) class a 5gallon foam bucket at .3 last ?

A

1500 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

can the TFT educter be used for class A foam?

A

yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

AFFF foam water based and good for

A

fuel spills

hydracarbon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

AR AFFF good for what type of spills?

A

alcahol based spills

IE acetone

17
Q

what foam is stocked at

logs

18
Q

advantages to protein foam

A

more durable and heat resistant blanket.

biodegradeable

19
Q

with class b foam

how long will 1 % last

20
Q

1 tank and 1 bucket of 1% will cover

A

300 square feet

(17’x17’ square)

21
Q

3 foam application methods

A

rain down

roll on

bank down

22
Q

what happens to the foam eductor if the back pressure is greater than 65-70%

A

foam cannot be made

23
Q

can automatic nozzles be used with eductors?

A

yes as long as hose length is under 200’

24
Q

gpm for TFT eductor

25
inlet pressure on TFT eductor
200
26
one feature of the elkhart that the other two dont have?
water only bypass
27
elkhart inlet size
2 1/2
28
tft and angus inlet size
1 1/2
29
elkhart foam percentages
1, 3, and 6%
30
angus foam percent
1-6%
31
TFT foam percents
.25 .5 1, 3, and 6%
32