Fixed Installations Flashcards

1
Q

What are the different types of Automatic fire alarms detector heads? 5 to name.

A

Ionisation

Optical

Radiation

Heat

Sampling detector

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the 3 different types of automatic sprinklers systems?

A

Wet- pipes permanently filled with water

Dry- have air under pressure to hold water back. Preventing water freezing in sprinkler pipes

Alternate- can be either wet or dry for where temperatures may vary.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the 3 functions of an automatic fire alarm system?

A

To detect a fire.

To raise alarm and indicate where fire is.

To raise alarm at central control centre.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the 3 functions of automatic sprinkler systems?

A

To detect fire

To attack fire

To give audible warning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are drenchers and what do they do?

A

Drenchers protect a building from fires in neighbouring buildings by deploying water to provide a protective barrier between the fire and the building.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How to water spray projectors extinguish a fire? 3 ways.

A

By cooling the surface of the oil (attacking heat).

By diluting the oxygen supply (attacking oxygen).

By diluting the burning liquid by emulsification (Attacking fuel).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

At what height must a building have a dry rising main?

A

18 metres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the sizes of dry rising mains and how many inlets would they have?

A

100mm pipes will have 2 inlets

150mm pipes will have 4 inlets

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the 5 advantages of a dry rising main?

A

Reduce hose required

Reduce friction

Lessen equipment needed

Stairways are kept clear

Reduces efforts needed to make the attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the heights at which a building must have a wet rising main?

A

In all buildings over 60 metres

In all building built since 2006 of over 50 metres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the 3 features a fire lift must have to be a fire lift?

A

Must be able to carry 8 people

Must be able to carry 850kg

Must be able to be controlled by a firefighter overriding key.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are foam inlets in terms of fixed installations?

A

To channel foam into areas where there is a flammable hazard.
This reduces risk to firefighters.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the danger with roller shutters with a fusible link?

A

The danger is if the fire melts the link the roller shutter could drop unexpectedly on fire fighters, on hose lines or trap firefighters.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What pressure is a dry rising main initially charged to?

A

10 bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the maximum pressure a fixed installation hose reel is charged to?
What is the working pressure and flow rate?

A

Maximum pressure- 7 bar

Working pressure- 2 bar
Flow rate of 140 litres per minute.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What extinguishing media are used in extinguishing systems other that water?

A

Carbon dioxide
Dry powder
Halogenated hydrocarbon (Halon)

17
Q

What are the 2 types of extinguishing systems for fixed installations?

A

Total flooding systems- enough to flood a confined space to extinguish the entire area.

Local application system- cover a specific hazard