T or F all lines at taxpayer fires must be 2 1/2
F. when medium or heavy fire conditions initial lines should be 2 1/2. 1 3/4 can be used in exposures
1st engine at a taxpayer fire cellar fire
into the occupancy above the fire. If there is an interior stair first line must be stretched to this point. advance down if possible
2nd line at taxpayer cellar fire
if interior stairs are present and 1st line advanced second line must be stretched to the top of the stairs
who ensures sprinkler is supplied at taxpayer fire
3rd engine
can second engine stretch a line at taxpayer fire
only if they supplied the sprinkler first and conditions permit
cockloft fire in a taxpayer where fire has control of cockloft and exposure protection is critical what should first engine do
position apparatus to utilize deck gun, consider inline pumping, save room for TL, if exposure problems stretch to most severe exposure
cockloft fire in a taxpayer where fire has control of cockloft and exposure protection is critical what should second engine do
assist first engine with stretch into exposure, or if conditions permit stretch second line into another exposed building/occupancy, may be advisable to skip stores
3rd engine at a cockloft fire in taxpayer
ensure sprinkler is supplied, stretch a line as ordered by the IC
who shuts utilities in a taxpayer fire
1st ladder company, if in the basement two masked members shall be disaptched
cellar fire in a taxpayer who brings first saw to the roof
2nd due roof
where do the 1st and 2nd due LCC go for cellar fire in a taxpayer
join forcible entry team unless directed otherwise
where do fires typically originate in taxpayer
street level in the storage or utility area in the rear
cellar fire in a taxpayer who do we need to communicate with in order to take store front windows
1st due truck officer
store fire in a taxpayer who authorizes removal of storefront windows
IC. charged line must be in place
who brings first saw to the roof at store fire in a taxpayer
first due roof
cockloft fire in a taxpayer where do the LCC’s go
1st LCC proceed to the roof, 2nd LCC join inside team or as directed
class J alarm between 1900-0700 who responds in emergency mode
1st due units
Class J alarm from 700-1900 who responds in emergency mode
its a single unit response between these hours and the company responds in emergency mode
is a manhole fire modified response for second due companies
no, manhole emergencies are
class J alarms how long does officer wait at the panel to make sure the reset holds
2-3 minutes
how many turns to shut the buckeye pipeline
42 full turns clockwise
In HRFPMD venting of the fire apartment should not take place until the fire is
controlled
elevator machinery room doors should not be used for ventilation until the fire
under control-as long as wind will not force smoke back into the building
in HRFPMD the FAST unit and CFRD engine shall be assigned to the fire sector when the fire is above what floor
fires above the sixth floor they can be staged on the floor below the fire, for fires sixth floor and below IC determines the location they will stage
HRFPMD can we stretch off the standpipe is the fire is below grade such as in a cellar or below grade parking garage
it is advisable to handstretch but you can use standpipe if sprinkler system has controlled the fire and members will not be exposed
wind driven fire with a known life hazard, do you need to wait for alternate strategy to be implemented before you can attempt a rescue
you can attempt rescue WHILE alternate strategies are implemented
TorF to properly vent a window open it 2/3 from the top and 1/3 from the bottom
true
if you press an alarm box how far away can you hear the beeps
20ft
fire in a vacant rowframe that’s in a row of occupied, what does first engine do
drop a 3 1/2 for a TL and stretch a line into most severe exposure
second line for a fire in a vacant rowframe in a row of occupied frames
back up first line, if not needed to the fire building or other exposure
LPG tank fire, anyone not engaged in operations should be kept_______ft away from front and rear of tank and _______ft away from the sides
1000 ft from front/rear and 500 from the sides
boxer stance when operating a saw, feet are how far apart
18-20 inches
what tools can we use to cut a windshield of a car
beluga auto glass knife, Sawzall with wood blade, windshield handsaw, axe
which of the following leaves of absence can be deducted from annual leave balance: bereavement, legal appearances involving city business, first schedule tour of emergency leave, military leaves not exceeding 30 days annually
all of the above
who carries a fast pak on the rig
ladder, rescue, squad
incident vs collision- tree limb falls on apparatus apparatus fire damage discovered apparatus strikes a fixed object properly parked and struck by another rig
all are incidents except apparatus striking a fixed object
who directs the system control unit to monitor and control the HVAC system
IC
what kind of trusses stretch when losing strenght, wood or steel
steel, wood will snap
what is considered narrow frontage building and where do we place the aerial at these buildings
30 ft or less, center of the building
HRO order of actions for the HVAC system
Open outside air supply
open exhaust dampers
close mixing dampers
open outside, close mixing damper, open exhaust
OOCO
is concrete or gypsum flooring used in PDs
yes
psi required at the inlet of a TL
200-250
what is considered the most flexible type of LCS
akron TL based monitor
for casual exposures, do immediate notifications to BHS or car 32/33 need to be made
no
what type of loft is considered the newest and most common
fireproof
duties of the Checker FF at a cfrd run
patient assessment, checks for pulse and begins compressions
who completes PCR at a cfr run
defib/documenter FF
probie training notebook when does company commander review it
monthly and initial and date in red ink
who does not wear a HT at a water rescue op
primary and secondary rescuers, all other members do
if the fire is below the______floor the hook is not used for a FE stretch and the line is stretched up the stairwell
4th floor, secure the hose on alternate floors beginning on the floor below the fire
what type of extinguishers are effective on SMALL LP gas fires
carbon dioxide and dry chem
if members are permitted to leave during an investigation concerning auc 202 who must the investigating officer write a report to
CoD
TorF LPG is toxic and poisonous
False
TorF LPG is heavier than air
true 1.5-2 times heavier`
where can we find out of service signs for alarm boxes and who must place them if OOS
found at battalion headquarters and first due engine places them
in buildings under construction standpipe risers must be painted what color to be considered in a state of readiness
red
if its freezing outside standpipe risers must be maintained as a dry system in buildings under construction. do they need to have an air pressurized alarm
yes. wet if it is above freezing
at night time when looking for the standpipe connection at building under construction/demolition look for the________light
red
can construction personnel use a standpipe riser for water or compressed air at a building under construction
yes provided they maintain at least one other standpipe for firefighting purposes-same for buildings being demolished
in buildings under demolition what color must standpipes be painted to be in a state of readiness
red
buildings under demolition standpipe systems are wet or dry
dry
where does a standpipe riser need to be capped in a building under demo
above the outlet on the floor immediately below the one being demoed
buildings under demo is the sprinkler automatic or non automatic
NON automatic
where are sprinkler risers capped in buildings under demo
immediately below the floor being demolished-red paint must be maintained during any demo operations
what color light to indicate the sprinkler connection at night in buildings being demoed
red light
during construction at least one permanent stair shall be brought within______ft of the working deck at all times
40 ft or 4 floors
when a building under construction/demo reaches a height greater than_______ft at least one elevator or hoist shall be kept in readiness for FD use
75 ft
maximum distance between the highest accessible floor from a temporary elevator or hoist and the working deck shall be no more than________
75 ft
TorF all exposed piping for sprinklers and standpipes must be painted red
F-there are exceptions for branch piping
dedicated standpipe valve handles must be painted_____
red
dedicated valve handles for combination systems must be painted________
yellow
dedicated valve handles for sprinkler systems must be painted_______
green
what is the single best design feature to identify Class2 High rise residential building
horizontal bands or belt courses, they will be present on the wall that faces the street-can also be found on class 1 hrfpmd
where else can horizontal bands/belt courses be found on class 2 high rise md
usually found above windows of flrs 1,2,3
usually found below windows of any of the top 3 floors
also can be found on any floor
can you transverse from wing to wing in a class 2 high rise MD via the cellar, lobby, roof or a shared fire stair
yes to all
fire resistive high rise md can a fire stair bypass the lobby and begin in the cellar.
yes. they can also be terminate in the street
class 2 high rise md-ENCLOSED FIRE STAIRS usually contain a standpipe TorF
false they usually do not
class 2 high rise md-OPEN FIRE STAIR is the most common fire stair encountered, TorF
True-generally has two doors serving two apartments, usually does not have a standpipe
class 2 high rise md-SHARED FIRE STAIR-are they open or closed? and do they provide a crossover to the other wing?
shared fire stairs are open and they do provide access to the other wing. they are shared by apartments from two different wings
class 2 high rise md-SERVICE STAIRS- are they open or closed? do they contain a standpipe, elevators and the main entrance to the apartment?
open stairs, that usually contain a standpipe, elevator and apartment entrance, however this is typically NOT the main entrance
CLASS 2 HIGH RISE MD-who must a FF notify before using a fire escape
their company officer
standpipe outlets in class 2 high rise can be found up to______ft high
7ft
what type of elevators typically provide access to standpipe and stair areas in class 2 high rise
service elevators-they may not have fireman service and may require manual mode for firefighting ops-we can still use them
TorF building personnel and occupants are a good resource to stair locations and access/egress points in class 2 high rise
false. building personnel yes, occupants no
in class 2 high rise md, if occupants are evacuating from upper floors what do we do
instruct them to remain in their apartments if conditions allow
TorF in class 2 high rise always use the enclosed stair as the attack stair
False, sometimes we may have to use the enclosed stair for evacuation
class 2 high rise can we use 1 3/4 hose
no. 2 1/2 off the rig or standpipe only
class 2 high rise md-if the PRD cannont be removed who must be notified
engine and ladder officers
class 2 high rise md-if the third due engine is helping with the first line who must be notified
IC and 4th due engine officer
class 2 high rise TorF the first ladder inside team, OV and 2nd OV will operate as per HRFPMD
T
class 2 high rise TorF the first due roof and LCC will typically operate as per HRFPMD
false, LRFPMD
class 2 high rise who decides if roof access for venting will be attempted
first ladder officer
how many members must be assigned to vent the roof if the stairs are not an IDLH
2 members if it is an IDLH or not
what members can assist the first roof in venting the roof in a class 2 high rise
2nd roof, 1st can man or 1st FE.
fire apartment door must be controlled until 2 members are on the roof or attained an area of refuge. officer must notify these members if the door cannot be controlled
who assists with KO curtain deployment or LSR rescue if necessary in a class 2 high rise
2nd due OV
who must the first due OV notify if they are going to operate on a class 2 high rise
first due truck officer
first roof FF tools at class 2 high rise
Halligan, maul/axe, and hydraram. does not bring LSR
-remember it as brings less tools so he can be faster
LRFPMD a 35 foot portable can typically reach what floor
4th floor
second due roof FF tools at class 2 high rise
halligan hook, halligan, LSR and life belt-prior to proceeding to the roof bring LSR to floor above. If fire floor is top floor or floor below that proceed to roof with LSR
Roof access in order of preference for Class 2 high rise
remote unaffected stair with roof access
adjoining building aerial ladder
fire escape open stairs
remote unaffected stairs adjoining building aerial ladder-usually not a viable option fire escape open stairs
for a top floor fire in a class 2 high rise, who ensures the KO curtain is brought to the roof
2nd due truck officer
TorF second ladder officer inside team tools include a search rope and KO curtain at a class 2 high rise
true
second due inside team at a class 2 high rise, who must you notify if there is a trapped occupant in fire apartment
first ladder officer and IC
where is the scuttle ladder usually located in a brownstone
top floor inside a closet
how big is the cockloft in a brownstone
2-3 ft
where can we find very small windows in a brownstone at the ground level
in the rear-could be useful for venting a cellar fire
in a brownstone who does the Roof FF notify if rescue ops are not needed
LCC…notify the officer if rescue if there is a rescue operation needed
who does OV notify if rear rescue is needed in a brownstone and ladder ops is practical
IC-initially they need to notify IC and company officer that there is a trapped occupant and exact floor and location
10 ft scissor ladder allows access to the roof of a ______story setback at a brownstone
1st
10 ft scissor ladder offers access to the ______floor from the roof of the 1st floor setback at a brownstone
3rd
fire on two floors of a brownstone is
extra engine and truck
if a child states they are abused and doesn’t want to return home what actions must we take of the following
- notify dispatch company is only in service for Fire duty
- request PD and EMS supervisor and ambulance
- take the child In protective custody until NYPD arrives
- EMS fills out the mandated report of suspected child abuse
all are true except we are OOS for all runs
If a civilian requests assistance who must we request to the scene
NYPD, go OOS for assist civilian and fill out letterhead report including name of civilian, Identity of Police officer. report goes to chief of OPS
do companies go OOS for operation sidewalk
AUC 4
engine or ladder company is in service by radio and responds at discretion of dispatcher. will respond to all 10-75 or greater
third and fourth grade classes will have one supervisor for every_____kids
15
fifth grade and over will have one supervisor for every______kids
30
school visits shall be no more than_____duration and between what hours
one hour and 0900-1700
classes below third grade shall have one supervisor for every______kids
four
scout troops shall have one adult for every______scouts
twenty
you receive a 10-51 do you still go out for operation sidewalk
no
AUC 149-TorF foam solution must be carried on all apparatus and additional cans of foam solution shall be stored with spare wrenches for use by relocated units
False. FOAM SOLUTION, everything else is true
AUC 149, TorF Engine companies responding from quarters, should place additional foam on the rig
True, if not in quarters do not return to quarters for additional foam
AUC 149 if we cannot shut down valves because need to protect life who must be immediately notified
dispatcher
AUC 149, which do we extinguish first, ignition sources close to leak or ignition sources in the path of drifting vapors
sources in the path first, only if there is a strong wind
in order to make a path for rescue at a pipeline leak use a solid hose stream a few inches above ground and move rapidly side to side to clear a path for rescue. TorF
True
Dept apparatus should not be brought closer than______ft to a pipeline leak
600 ft
AUC 149 company commanders shall notify who for needed repairs or recommendations concerning the buckeye pipeline
letterhead report to the pipeline coordinator at div 8
critical repairs require an immediate telephone notification
flooded valve pits on the buckeye pipeline require immediate telephone notification to the buckeye pipeline coordinator. TorF
true, also must inspect valve pits prone to flooding during sub-freezing weather
Can BFU winches tow full size apparatus
no
TorF at a brush fire we can operate a hoseline under high voltage lines to protect an exposure
FALSE-never operate hoselines beneath hight voltage lines
can we operate in front of a brush fire to protect exposures
no avoid operating in front of brush fires, but we can only to protect LIFE and sufficient lines must be in place
how do we apply water into a manhole fire
let it flow or pour into manhole, only when directed by con ed employee
at manhole emergencies, the location of_______must be taken into consideration when deciding the size and location of danger area
traffic control boxes
PCB contaminated transformers contain how much PCB
50-499ppm PCB
what is the greatest hazard in transformer vaults
electricity
can we use foam at a fire in underground transformer vault
yes, may need to consider foam op bc of the amount of flammable liquid
after receiving approval to enter an underground transformer vault what kind of search shall be conducted for victims
cursory
what kind of fires is fire and ice effective on
class C fires involving electrical cables, It is NOT effective on class B fires
size and length of hose used for fire and ice
25 foot length of 3/4 inch hose
what size hose to supply fire and ice operation
1 3/4 hose
TorF the IC, company officer or Chief can order the application of fire and ice
false only a chief officer, can do so without con ed on scene
operating pressure at the nozzle for fire and Ice operation
60-100psi, 60-80 is optimal. pressure must be determined at the pump panel
where do we place the container of fire and ice product at an operation
at the point of nozzle operation. member operating the pick-up tube will employ a circular motion
where do we commence nozzle operations at a fire and ice operation? and what is the minimum safe distance while operating
commence at 50ft, minimum safe distance is 25ft
it says to use a dry length of hose to safely measure distance
TorF we can use the pick up tube and hose at a fire and ice operation even if it is wet
false, cannot be wet before use or reuse
when does certain equipment need to be assembled in readiness for winter ops
October 1st
how many extra lengths of hose rolled or folded do engines and trucks need on the rig for winter ops, and what size is it
6 extra lengths of 2 1/2, also two shovels, salt or sand, vehicle recovery strap, tire chains and tool, specialized hydrant connection set up as determined by company commander
company commander shall requisition supplies for winter ops starting_______? if not received by______ notify division coordinator
start July 1, if not received by October 1 make notification
how many shovels needed in quarters for snow clearance
6
what color disc put on a frozen hydrant
yellow
what is considered sub freezing temperature
25 degrees or less
can we put in a work order in the Hansen hydrant application for a hydrant not in our district
notify the officer of that unit to do it
winter ops and the building is higher than three stories who should enter the block first
trucks
TorF an engine should never back down the block during a snowstorm
False, they should consider this for better traction
can we hook directly up to hydrant initially if need during winter ops
yes, must put a two way gate on if we do
if a hydrant is reported fixed and you check the hydrant and find it still broken, how do you report this
re-enter in Hansen application
of the following what is not one of the conditions need to be met in order to issue a hydrant spray cap
- 16 years old
- they fill out the spray cap form
- hydrant is not on two way street or other main traffic aretery
- cap is not placed on a hydrant located on a main larger than 20 inces in diameter
person must be 18 years old. everything else is true
to relieve members at a job within______ at the change of tours members shall proceed on foot or public transit
1/3 of a mile
no company shall remain in quarters later than ______or______before proceeding to operations or relocated quarters
0930/1830
units scheduled for training shall leave quarters no later than______or ______
0915/1815
the officer or a relocated unit shall notify who that relief may be required and at what time is notification made
notify dispatcher of borough you are relocated to, and do so at 0800/1700
auc 230, members entering rehabilitation shall rest for approx______minutes before being reassigned
20 minutes
if we need to use the padlock to secure a commercial occupancy after a minor fire where do we secure the key
on the apparatus
company commanders shall forward a report to ______in order to rescind Chauffeur status
CHief of Ops
chauffeur form CT-1 shall be forwarded to admin division by company commanders when?
feb 1st and august 1st
of the following units which must start the tour with two school trained chauffeurs Satellite squad planning vehicle haz mat tech unit collapse rescue units decon unit and tractor trailer aparatus
all but the tractor trailer apparatus. they need one school trained chauf and one tractor trained chauf
of the following units which must start the tour with one school trained and one company trained chauf
foam unit
airport hose wagon
all. plus companies designated as back up units to all of the units that require two school trained chauf.
who does officer notify when a reserve apparatus is fully staffed and ready for fire duty
AUC 259
dispatch, BC, DC, tour command chief
how do we respond on the radio if we are operating reserve apparatus E506 and we are relocated to E249
E506 acting E249-do not use second or third section
how many riding lists do we need if staffing a reserve aparatus
three, third copy at housewatch desk of the unit whose identity you assume, or filed at emergency command post headquarters
TorF company commanders shall keep a separate cd14 for all reserve apparatus in their quarters
T
if reserve apparatus is used as a CFR unit how many trained members needed, and where do we get supplies from
2 members, do not use batt depot for initial supplies, but they can be used to keep the unit in service
satellite apparatus can pump up to ______gpm
satellite apparatus do not have pumping capabilities. They are hose wagons, satellite pumpers can pump up to 2000 gpm
what size hose do satellite units carry
6 inch
where does the officer ride when responding with a satellite unit, on the pumper or satellite apparatus?
pumper
Satellite units have two 3 1/2 inlets and one 4 1/2 inlet. which are gated and which do we supply first when operating multiple hoselines
3 1/2 are gated and supply 4 1/2 first
TorF the officer of the first to arrive satellite unit will become the water resource officer
True
TorF use the fireboat system to supply satellite units if conditions allow
True, this is better than putting high demand on the hydrant system
satellite water system-hydrants on a mainless than______inches in diameter it is recommended to be augmented by another pumper or second hydrant
12 inches. When supplied by drafting or by fireboat staellites are capable of delivering full capacity
Can satellite units be used to stretch and operate handlines at operations
yes
where do we position satellite apparatus for use of the deluge gun
far enough from building so as to permit deepest possible stream penetration
can a satellite officer order a deluge gun into operation
only the IC can
of the following which is not a core competency of the FDNY?
Structural Evac search and rescue
CBRN/Haz mat and mass decon
Arson cause and origin
all are core competencies
at an auto extrication or boat in distress who is in charge, NYPD or FDNY
whoever arrives first
NYPD has Haz mat CBRN incidents if terrorism is suspected or determined. If not terrorism it is unified
NYPD also has water/ice rescue
you have to detail a member to a nearby firehouse. One is on RSOT and one is on MSOT. who takes the detail
RSOT
when members do not return from a detail within the same borough, within_______minutes a notification must be made
60 minutes
if you are riding short who must you notify
admin div, admin batt and all first alarm companies, and take a mark in the journal
When positioning a tower ladder, the ideal horizontal distance from the centerline of the turntable to an objective is _______ feet. With the centerline of the turntable _______ feet from a building there will be sufficient room for the bucket to be dropped from the horizontal with the boom perpendicular to the side of the apparatus.
32/25
Members placed on Military Leave may be eligible for a maximum of _________ hours of paid Military Leave per calendar year.
240
The preferred placement of manual pins for TL outriggers shall be at the _____________ hole available once extended. The preferred placement of manual pins for jacks shall be at the ________________ slot available once extended.
lowest/highest
When removing a victim in a Stokes basket via the TL bucket, The ______ FF should perform the lowering operation if conditions permit
pedestal
If the TL bucket makes contact with a building, structure or other obstruction, a potentially dangerous condition may present itself. The TL bucket may become wedged or stuck. Should this occur members in the bucket should disengage the PTO, get low and turn off the apparatus. TorF
false, do not disengage PTO everything else is true
The Department of Transportation classifies chemicals according to their major hazardous characteristics. Which number would identify radioactive Material?
7
The pressurized water extinguisher weighs approximately 30 pounds and holds 2 ½ gallons of water, which will be expelled in ________ seconds.
55
The 2 ½ gallon water extinguisher shall be inspected ______ and after each use.
daily
The KO Curtain shall be inspected __________.
weekly, during MUD
who has training KO curtain
division
he officer of a company drilling with a Training KO Curtain that finds a defect with the curtain should telephone _____________.
tech services
If a portable generator is used to power an exhaust fan, the ideal length of the electrical cord should be _______ feet or less.
50ft
All ladder company apparatus are equipped with onboard generators that shall be checked __________.
weekly
Sure Search Door Markers should be placed on the outside doorknob when a team or member _______________________.
enters an area for primary search
At major operations, additional Sure Search Door Markers can be obtained from ____________.
field comm
The fuel tank on FDNY portable power saws is sufficient for _____-______ minutes of continuous operation
20-30 minutes
Belt adjustments and a visual inspection of the belt on the power portable saws should be done __________, and after every cutting operation.
weekly
When starting the portable power saw, pull the starter cord until you hear the motor kick. Disengage the choke and pull the starter cord. Once the saw starts disengage the trigger lock. Allow the saw to run for _________ seconds, and then slowly bring up the RPM to full throttle.
10-20 seconds
saw operations, If the Guide Man gives two slaps on the back of the Operator, the Operator should _____________
cut.
1 slap=stop cutting
2slaps=cut
3 slaps=shut down saw
When using the Rabbit Tool to force open an inward opening door, the door should open in _____ to ____ pumps of the handle.
3-4 pumps
can the rabbit tool be used as an auto extrication tool
no
what is max opening of the hydra ram
4 inches
10,000 pounds of pressure
requires no priming
opens 3/4 of inch per stroke
TorF we can replace the hydraulic fluid in the hydra ram
False, it uses no hydraulic fluid
the entire tool can be cleaned with soap and water
When activated, glow sticks will provide up to ______ hours of illumination.
12 hours
can we operate a chainsaw off a portable ladder that has been secured
no
TorF we must leave the fire area immediately upon feeling any pain or discomfort through the hood
False you can stay if It can be immediately cooled with a hoseline
TorF theproper procedure for donning bunker is
1) pants/boots 5)hood pushed down
2) HT
3) hood over head
4) bunker coat
True this is the procedure
prior to bunker being sent out for advanced cleaning company commanders shall ensure bunker is marked with the members first initial, last name and company in 1 inch letters. where is the marking made?
on the liner on the right side of the fly between Velcro closure and manufacturers label
where must “no bunker gear” signs be displayed
all entrances to living areas that adjoin an area where bunker gear is permitted
if bunker paints and pss are contaminated can we place them both is same clear plastic bag
no separate them
can we cut down a hanging victim if they are obviously dead and in public view
no, cover them
who do we call to voucher large amounts of currency
fire marshalls
After all Ambulatory victims have been removed during an under river rail operation, which victims should be removed next?
red tag non ambulatory
Blue Light Station Power Removal Boxes are located every _______ feet along the guideway within the JFK AIRTRAIN System
800 feet
Which ladder company is responsible to determine which stairway is the best stairway to be used by the occupants for evacuation at a fire in a High-Rise Office building?
third due truck
At loft buildings, __________ are fixed glass segments that are imbedded in cast-iron frames or masonry to provide natural light for sidewalk vaults.
deadlights
All of the following tools are listed as ineffective when dealing with LEXAN windows with the exception of which one?
a. Conventional forcible entry tools
b. Sawzall
c. Oxyacetylene torch
d. Superior Air Hammer (air chisel)
sawzall
The Purple K Dry Chemical extinguisher features are correctly stated in all but which one of the following choices?
a. Discharge time of 55 seconds
b. Discharge range of 19-20 feet
c. Coverage area of approximately 30 square feet
d. Can be used in temperatures between minus 40 and 120 degrees
discharge time is 11 seconds. Water can is 55 seconds
attic or cockloft vents are excellent locations to apply water for a fire in a place of worship? TorF
true-located a few feet above the rose window
All of the following are considered collapse hazards except?
a. Transept
b. Minaret
c. Steeple
d. Bell tower
transept
Older architecture churches have which of the following feature(s)?
Select one or more:
a. Ornate decorations
b. Buttresses
c. Large columns
d. Massive walls
all
When fire is located within the large open area of the place of worship, the first priority is?
TL stream through the Rose window
Following the control of a fire within the large open space by using a stream through the rose window, water application into the attic vent opening should then be the priority,. TorF
True
At first floor and choir loft fires in a Place of Worship, it is correct to state that If there is advanced fire, a 3rd handline is an initial consideration TorF
True