Fire/Smoke Detection Flashcards

1
Q

Fire bottles are

A

Electrically operated manual selection by flight crew

Based upon automatic fire detection

Each engine has two fire extinguisher bottles available which are connected to fire zones via piping

Release the content if the cartridge is broken

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens when you pull the fire warning handle

A

Fire bottle squib will be armed

  • closure of fuel shut off valve
  • closure of hydraulic shut off valve
  • closure of engine bleed air valve
  • tripping of generator breaker
  • disabling the engine thrust reverser
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Gas filled fire detection system error warning means

A

Low Pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Gas filled detection system fire warning means

A

High pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Gas filled fire detection system

A

If the gas in the pipe is heated pressure rises to warn the presence of fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Optical Smoke Detector

A

Particles of smoke scatter and reflect light
Detector has a light source and a sensor
If two or more detectors sense smoke it will trigger alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Ionisation Smoke Detector

A

Small quantity of radioactive material in ionising chamber
Smoke particles absorb alpha particles
Ionisation stops so current flow stops
Lack of current flow triggers warning on flight deck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

APU Fire Zone

A

Self contained/automatic detection will cause APU to shut down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Fire wire - Fire Detection

A

Operates on principal wire will change its resistance when heated
Can be operated with one loop for limited time
Each loop is independent of other and own controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Systron Donner - Gas Filled Detector

A

Two loops which gas expands to push out warning circuit

Core contains helium gas 8psi
If loop breaks gas leaks and responder unit will signal fault

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Bimetallic overheat sensor

A

Two metallic strips with low efficient of expansion
Electrical contact
Heat stretch them apart

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Armed condition for fire warning in cockpit

A

Pulling fire warning will

Cut of generators
Cut of fuel supply low pressure spar valve
Cut of hydraulic supply
Cut of bleed air/HPSOV
Detonator arms the fire extinguisher squib

Can be reversed apart from generators is pushed back in

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

After arming the fire warning what is the next step

A

Rotate the red button which will fire the squib

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When fire is detected

A

Red flashing fire master caution captions (will not go out until fire detection is removed)

Sound of fire warning bell
Illuminate the ENG1 FIRE
Illuminate appropriate fire handle in cockpit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Fire extinguisher system is a

A

2 shot system capable of sending extinguishing to either engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Toilets have what fire smoke/fire protection

A

Smoke detection is ionisation type
Automatic fire extinguisher straight into the waste paper bin
Freon/BCG extinguishing agent

17
Q

Fire extinguishers in engine

A

Operated by electrically fired cartridge (squib) rupturing a seal in the bottle head

Extinguishing directed to low pressure end of the engine compressor

X2 per engine

Halon extinguisher used

18
Q

Fire Wire faults meaning

A

Low resistance and low capacity - loop is faulty

19
Q

Indications of successful engine fire drill

A

The engine fire handle or button light goes out

20
Q

What warnings of an engine fire system can be cancelled

A

The audible warning and attention getting light

Red fire captions illuminated until fire is no longer detected

21
Q

Firewire works on a negative of what

A

Negative coefficient of resistance and a positive coefficient of capacitance

22
Q

Smoke Detection requirements in flight deck

A

No required

23
Q

Where would you find smoke detectors

A

Galleys, toilets and inaccessible compartments and worse case scenario area

  • hydraulic bays
  • cargo bays
  • avionics
  • electrical bays
  • engines
  • APU
  • Cargo compartments
24
Q

Continuous Loop Fire detection system

A

Thermal detector that monitor temp and heat and responds with signal when temp exceeds limit

Changes electrical resistance with temp - as temp goes up resistance goes down and current increases. Can be reset once fire is removed as resistance will then increase again

Dual loop system both need to be triggered to activate fire warning

25
Q

Minimum loops for a 2 engine ac

A

2 loops minimum
One loop has 2 shots

26
Q

Why do bimetallic detectors have a delay before triggering

A

In order to avoid false indications caused by vibrations

27
Q

Key facts about halon extinguisher

A

Suppresses the chemical reaction of fire
Most effective fire extinguisher
Is not corrosive on aluminium