Fire Safety Flashcards
What is the Fire Safety Act 2021?
The act requires the responsible person of multi-occupied residential buildings with two or more domestic premises to update their FRA to include an assessment of the building structure, external walls and flat entrance doors.
Updated Feb 2023
What is the Fire Safety (England) Regulations 2022
January 2023, under article 24 of the Fire Safety Order 2005. For high rise buildings over 11m & all multi-occupied residential buildings with 2 or more domestic premises and make it a requirement for responsible persons of high rise buildings to provide information on their buildings to their local Fire and Rescue services.
*Plans
*External wall systems
*Lifts
*Fire fighting equipment
What is the Minimum Lux levels for emergency lighting?
Minimum of:
1 Lux = Escape route
0.5 Lux = Open Area
10% of Normal Conditions = High Risk
What foam was used at Wycombe High School?
We specified intunesent foam.
Contractor to provide proposal, for approval. When provided with data sheet we checked it was suitable.
*Blue 60 Fire rated frame foam
*7 - 30mm gaps
What is a type of Fire Rated Glass?
Pilkington Pyrodur.
What is the depth of a door liner on a Fire door?
25mm
What are Quartzoid bulbs in a sprinkler system?
The bulbs burst in high temperatures and water flows from the sprinkler heads.
What is an asperation detection system?
A highly sensitive form of fire detection system that can detect a fire at an early stages, through air samples that test for the presence of smoke.
What was the manufacture used for the Fire batts used at WHS?
- Rockwool Fire Barrier System
- Rockwool insulated Fire sleeves
What is BB100?
Non-statutory guidance on Fire Safety in schools specifically relating to access, building structure and minimising spread of Fire.
What is BS476?
A British Standard for Fire tests on building materials and structures.
What is the difference between Integrity & Insulation?
- Integrity = Resistance to Fire.
- Insulation = Will stop the transfer of heat.
What is the Building Safety Act - April 2022?
What is an accountable person?
Provides a framework for the design, construction and occupation of “High risk residential buildings”. Which are buildings at least 18M or 7 storey in height and comprises of at least 2 domestic premises to support Fire Safety and Building Regulations.
It also introduces a new duty holder “The accountable person”.
A person who holds a legal estate in possession in any part of the common parts or relevant repairing obligations (but not holding legal estate) of the common parts.
What is the Regulatory Reform (Fire Safety) Order 2005?
A Framework for regulating Fire Safety in all non-domestic premises & the parts of multi-occupied residential buildings.
What is the Hackett Report?
May 18 , Dame Judith Hackett published “Building a safer future; Independent review of Building Regulations and Fire Safety” following Grenfell Tower tragedy the previous year.
Recommendations were as follows:
- Banning Combustible Materials.
- Large Scale Testing Regime.
- Duty Holder Responsibilities.
- Improved Fire Risk Assessments.