Fire Protection Systems Flashcards

1
Q

How can you determine the state of charge of a CO2 fire extinguisher?

A

By its weight.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How can you determine the state of charge of a freon fire extinguisher container?

A

By the pressure shown on the built-in gauge.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How does the ambient temperature affect the pressure shown on the pressure gauge on a freon fire extinguisher?

A

The higher the temperature, the higher the pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How can you determine whether or not a built-in fire extinguishing system has been discharged?

A

By checking the blowout plugs on the outside of the aircraft near the extinguisher agent bottles.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is indicated if the red disc in a built-in fire extinguishing system is blown out?

A

The agent bottle has been discharged because of an overheat condition.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is indicated if the yellow disc in a built-in fire extinguishing system is blown out?

A

The agent bottle has been discharged by the flight crew actuating the Bottle Discharge switch.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly