Fire Protection Flashcards
WHICH OF THE FOLLOWING AGENTS IS USED IN THE TWO ENGINE FIRE BOTTLES:
FREON OR HALON, PRESSURIZED BY NITROGEN
HOW MANY ENGINE FIRE EXTINGUISHER BOTTLES ARE THERE?
TWO COMMON FOR BOTH ENGINES
EACH ENGINE IS EQUIPPED WITH:
TWO FIRE DETECTION LOOPS MOUNTED IN PARALLEL
WHICH OF THE FOLLOWING BUSSES POWER THE ENGINE FIRE DETECTION SYSTEM, THE FIRE
HANDLES AND THE EXTINGUISHER BOTTLE DISCHARGE SYSTEM:
DC EMER BUS
WHAT AURAL WARNING IS GIVEN IN CASE OF A FIRE WARNING OR A SMOKE WARNING:
CONTINUOUS REPETITIVE CHIME
WHAT HAPPENS WHEN THE “SQUIB TEST” PB IS DEPRESSED?
DISCHARGE HEADS ARE TESTED AND THE TWO SQUIB LIGHTS ILLUMINATE WHITE
WHAT HAPPENS WHEN THE “FIRE TEST SW” IS DEPRESSED IN FAULT POSITION ON THE
ENGINE FIRE?
LOOP A AND LOOP B FAULT LIGHTS ILLUMINATE
FWS IS ACTIVATED, LOOP ALERT IS DISPLAYED ON THE EWD WITH ASSOCIATED “LOOP”
LABEL. MASTER CAUTION LIGHT FLASHING WITH AURAL SINGLE CHIME
A/C ON GROUND, SUPPLIED BY BATTERY ONLY, BOTH CONDITION LEVERS IN SHUT-OFF
POSITION, THE FIRE TEST WILL OPERATE:
ENGINE FIRE LIGHT ON FWS AND IN FIRE HANDLE, MASTER WARNING LIGHTS AND CRC
IN CM1 LOUDSPEAKER
TO GET THE FIRE WARNING ON, IT IS NECESSARY TO HAVE:
ONE LOOP ON ONLY, BUT THE OTHER AT OFF
BOTH LOOPS ON
ENGINE FIRE TEST, LOOP PBS DEPRESSED (IN), WHAT HAPPENS IF ONLY ONE LOOP SENSES A
FIRE:
Nothing
WITH ONLY ONE LOOP PB IN ON POSITION (THE OTHER IN OFF), WHAT HAPPENS IF IT
SENSES A FIRE:
FIRE WARNING IS INITIATED
WHEN AN ENGINE FIRE WARNING APPEARS, WHICH WARNINGS ARE INITIATED:
ANSWER A + FUEL SHUT-OFF RED LIGHT IN THE ASSOCIATED CL (PROVIDED CL ISN’T IN
THE FUEL S/O POSITION)
THE FUEL SHUT-OFF RED LIGHT IN THE CL ILLUMINATES:
DURING A REAL FIRE (CL ISN’T IN FUEL SHUT-OFF POSITION)
IS IT POSSIBLE TO DISCHARGE A FIRE BOTTLE WITHOUT PULLING THE FIRE SHUT-OFF
HANDLE:
No
WHEN YOU PULL THE ENG FIRE SHUT-OFF HANDLE, WHAT HAPPENS:
PROPELLER FEATHERING, FUEL ENGINE LOW PRESSURE VALVE CLOSURE, AIR BLEED
VALVE AND HP VALVE CLOSURE, DE-ICE VALVE AND SHUT OFF VALVE CLOSURE, ELECTRICAL DC AND ACW GENERATORS DEACTIVATION, SQUIB LIGHT ILLUMINATION, EXTINGUISH AGENT PB IS ACTIVATED