Fire Ground Hydraulics Flashcards
1
Q
IOP Highway & Blitz Line
A
125psi
2
Q
IOP Pre-Connect Cross-Lays
A
150psi
3
Q
IOP Blitz line w/ Wye, 1 line
A
130psi
4
Q
IOP, Blitz line w/ Wye 2 lines
A
150psi
5
Q
IOP Sprinkler System @ FDC
A
150psi
6
Q
IOP if not listed
A
125psi
7
Q
Friction loss: Standpipe
A
25psi + Back-pressure
8
Q
Friction loss: Portable Monitor
A
15psi
9
Q
Friction loss: 4 Way Monitor
A
15psi
10
Q
Friction loss: Wye or Siamese
A
0psi
11
Q
Nozzle pressure: Handheld Fog
A
100psi
12
Q
Nozzle Pressure: Masterstream Fog
A
100psi
13
Q
Nozzle Pressure: Masterstream Smooth Bore (SB)
A
80psi
14
Q
Back or Head pressure (+-): psi per foot
A
.5
15
Q
Back or Head pressure (+-): psi per floor
A
5 psi per floor (above first floor)
16
Q
Friction loss Coefficient : 1”
A
150
17
Q
Friction loss Coefficient: 1 1/2”
A
24