On a small passenger vessel, 58 feet in length, carrying 52 passengers the fire pump shall have a minimum pumping capacity of___________.
50 Gallons per Minute
A length of fire hose shall be _____________.
Attached to a fire hydrant at all times
How many portable B-I fire extinguisher(s) are required at the operating station of a small passenger vessel? (small passenger vessel regulations)
One B-I extinguisher is required
Your vessel must have a B-II fire extinguisher. Which extinguisher fulfills this requirement? (small passenger vessel regulations)
15 lb. carbon dioxide
A length of hose with nozzle attached shall be attached to each fire hydrant at all times. TRUE or FALSE? (small passenger vessel regulations)
True
If your vessel is required to have a fire ax on board, where should it be located? (small passenger vessel regulations)
In or adjacent to the primary operating station.
How many portable fire extinguishers are required to be located inside the machinery space of a small passenger vessel?
None are required
On vessels that are required to have fixed carbon dioxide fire extinguishing systems, the controls to operate the system shall be installed in an accessible location _________________. (small passenger vessel regulations)
Outside the space protected
Fixed carbon dioxide fire extinguishing systems shall be installed to protect enclosed machinery and fuel tank spaces of all vessels using gasoline or other fuel having a flash point of_____________. (small passenger vessel regulations)
110 degrees Fahrenheit or lower
What would be an example of a B-I extinguisher? (small passenger vessel regulations)
2 pound dry chemical