Fire & Emergency Flashcards

1
Q

A fixed carbon dioxide extinguishing system for a machinery space, designed with a stop valve installed in the line leading to the protected space, is actuated with __________.

A

two independent controls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A grade “A” petroleum product is __________ .

A

a flammable liquid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A portable foam fire extinguisher carried aboard a tank vessel must be recharged every ______.

A

12 months

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

A vessel carries a total of ten B-II CO2 fire extinguishers. How many spare extinguishers must the vessel carry?

A

One

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

According to U.S. regulations, how many emergency outfits are required to be carried onboard all tankships over 1,000 gross tons?

A

Two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

According to CFRs, open tank hatches from tanks which are not gas free, and unattended, must be protected by __________.

A

flame screens

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A grade “E” combustible liquid is one having a flash point of 150°F or above. An example of a grade “E” product is __________.

A

engine lubricating oil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

According to Coast Guard Regulations (46 CFR), a 10 pound dry chemical extinguisher is equivalent to a __________.

A

15 pound CO2 fire extinguisher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

According to Coast Guard Regulations (46 CFR), on a freight vessel, each fire pump must be capable of supplying the two highest outlets simultaneously, at a Pitot tube pressure of __________ .

A

50 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A grade “E” petroleum product is __________ .

A

a combustible liquid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

According to Coast Guard Regulations (46 CFR), which of the listed CO2 (carbon dioxide) fire extinguishers by size is classified as B-II?

A

15 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

According to U.S. Coast Guard Regulations (46 CFR Part 34), if a fixed foam system is activated aboard a tank vessel, the foam supply must be sufficient to last for a minimum of __________.

A

three minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

According to U.S. Coast Guard Regulations (46 CFR), portable Halon fire extinguishers used on a MODU may be charged with __________ .

A

Halon 1211 only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
According to Federal Regulations, a confined or enclosed space that is being prepared for crew members to enter, should be tested and designated "NOT SAFE FOR WORKERS" if the oxygen content of the atmosphere in the compartment is less than \_\_\_\_\_\_\_\_\_\_ .
A	13.50%
B	15.50%
C	17.50%
D	19.50%
A

D 19.50%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Actuating the fixed CO2 system should cause the automatic shutdown of the __________.

A

supply and exhaust ventilation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

An example of a combustible liquid is _____.

A

lube oil

17
Q

After a fire has been extinguished in a closed space, personnel may safely enter the space when __________ .

A

all smoke and toxic fumes are removed and an adequate oxygen supply is present

18
Q

All fire hoses on mobile offshore drilling units must be tested to a pressure of at least __________.

A

100 psi

19
Q

Any liquid which gives off flammable vapors at or below 80°F, as determined by flash point from an open cup tester, describes a __________ .

A

flammable liquid

20
Q

Any liquid with a flash point above 80°F is a __________ .

A

combustible liquid

21
Q

Aqueous film forming firefighting foam is also known as __________.

A

mechanical foam

22
Q

As a general rule of thumb, with no adverse wind conditions, approximately how far could a straight stream of water reach from a fire hose having a nozzle pressure of 100 psi?

A

100 feet

23
Q
Before entering any space that has been sealed, its oxygen level should be tested. What level of oxygen in the space is equal to fresh air?
A	10.0%
B	15.8%
C	20.8%
D	25.8%
A

C 20.8%

24
Q

Before releasing the CO2 into the space, the alarm for a fixed CO2 system must sound for at least __________.

A

20 seconds

25
Q

Besides heat, fuel, and oxygen, which of the following is necessary for a fire to exist?

A

Chain reaction

26
Q

Bunker C is classified as a grade ______.

A

“E” liquid

27
Q

By definition, an example of a flammable liquid is __________.

A

gasoline

28
Q

By definition, combustible liquids are liquids which __________.

A

have a flash point of 80*F or higher

29
Q

By definition, spontaneous combustion is a result of __________.

A

chemical reactions within a substance