Fire code Flashcards

1
Q

Any act that would remove or neutralize a fire hazard

A

Abatement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

An integrated piping system connected to a source of extinguishing agent which suppresses fires when actuated by its automatic detecting device

A

Automatic fire suppression system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The head of the city fire starion ot the municipal fire station

A

Fire marshall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

A system of vertical pipes in a building to which fire hoses can be attached on each floor

A

Standpipe system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A wall designed to prevent the spread of fire

A

Firewall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The firewall having a fire resistance rating of not less than

A

4 hrs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Building 15 mts or more in height

A

High rise building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A continuous and unobstructed route of exit from one point in a building to a public way

A

Means of egress

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The purpose for which a bldg or space is used

A

Occupancy

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The max number of persons that may be allowed to occupy a particular bldg or space

A

Occupant load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A bldg that is unsafe in case of fire because it will burn easily or because it lacks adequate exits

A

Fire trap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Falar

A

Fire and life safety assessment report

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

All bldgs

A

Falar 1 & 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Bldgs with occupant load of at least 50

A

Falar 3 (anually)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Prepared by archi and fire protection consultant; fire and life safety features of the facility; plans and specs and design analysis

A

Falar 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Submitted by contractor; all approved submittals test forms, acceptance forms

A

Falar 2

17
Q

Periodic maintenance and upkeep of facility

A

Falar 3

18
Q

Fsec

A

Fire safety evaluation clearance

19
Q

Fsic

A

Fire safety inspection certificate

20
Q

Bldg permit

A

Fsec, review, falar 1

21
Q

Occupancy permit

A

Permit, fsic, inspection, falar 2

22
Q

Business permit

A

Renew, fsic, inspection, falar 3

23
Q

Route of exit, minimum width

A

915mm

24
Q

0-499 occupant load

A

2 exits

25
Q

500-1000

A

3 exits

26
Q

1000 or more

A

4 exits

27
Q

Indiv room with max 6 occupant load, travel distance to exits

A

15 meters

28
Q

Headroom

A

Min 2.00m

29
Q

Self closing mechanism for exit doors, clear opening

A

710mm-1220mm

30
Q

Handrails

A

760mm-865mm

31
Q

Travel distance to exits w/o sprinkler system

A

46m

32
Q

Travel distance to exits w sprinkler system

A

61m

33
Q

Seating: rows of seats b2b

A

830mm

34
Q

Back to one seat to front of the next seat

A

300mm

35
Q

Seats between aisles

A

14 maximum

36
Q

Seats between wall and aisle

A

7 maximum

37
Q

Seats without arms

A

600mm/person