Means of Egress-Ceiling Height
not less than 7 feet 6 inches (90 inches)
It is unlawful to alter a building or structure in a manner that will reduce the number of exits required by code. The exception is detached one and two family dwellings and townhomes not more than ___ stories above grade.
3
Headroom, protruding objects: Provide _ inches below pylons and 80 inches minimum above finished floor
27 inches
Post Mounted Objects-Free standing objects mounted on a post or pylon shall not overhang more than _____inches where the leading edge is more than 27 inches & less than 80 inches above finished floor.
4 inches
Horizontal Projections: Fixtures and furnishing shall not project more than ____ inch into required width of an exit.
1 1/2
Handrails can protrude into pathway but shall not exceed ___inches
3 1/2
this is an exception for group I-2
Manual pulls and alcohol based rub can project up to ____ inches
4 inches
standard is 4.5- ( exception is 3.5 for handrails for group I-2 and 4 inches for alcolol based hand rub)
minimum depth of a stair tread is ___inches
11 inches
Everyroom or space used for assembly of ___ or more shall have the occupancy load posted in a conspicuous place near the main exit or exit doorway?
50 or more people
Occupancy load signs shall use _____ inch minimum lettering.
1/2 inch or 13mm
When two or more utilize the same egress, the _____________requirement shall be met?
More stringent requirement shall be met
Any area without fixed seating, divide floor by Occupant load factor assigned to the ___________?
Function of the space
Seating booths shall provide ______inch per person
24 inches per person
Increase occuapny load. Provide ____feet per person
7 feet
When a door is fully open uit shall not reduce the width of egress by more than ____inches
7 inches
Occupant loads with ____ to _____ people shall have 2 exits
1 to 50
Exit Access: when occupancy load is 501-1,000 provide ___exits?
3 exits
No manager or “person in Control” shall allow the use of the room without providing required exits required by title 19 and title ___?
Title 24
Illumination: Means of Egress: Provide ___ foot candle (11) lux minimum?
1 foot
Emergency power illumination, means of egress, provide 11 lux minimum but can decline to 6 lux at any point and .6 at end of duration. Lighting shall not last less than ____minutes?
90 minutes
Elevators are required on all buildings __ or more stories in height?
4 stories
Areas of refuge: Shall accommodate __ wheelchairs but area not less than 30x48
2 wheelchairs
Areas of Refuge: Shall provide not less than ____ minutes of protection
90 minutes of protection
Areas of Refuge: separating exterior wall shall be rated at ____ hour minimum. Fire wall shall extend 10 feet beyond landing.
1 hour