FCOM Flashcards
ACW GEN 1 supplies…
ACW BUS 1
ACW SVCE BUS
ACW GEN 2 supplies…
ACW BUS 2
TRU is supplied by…
ACW BUS 2
BPCU functions…
BTC operation
Moniters HOTEL-mode
Isolates failed busses
Auto load sheds
ACW comes online
70% NP
Starter/generator transits…
0-45% NP Starter
61,5% > NP Generator
TCAS RA’s inhibit when…
below 1100’ in climb
below 900’ in descend
Decends:
below 1200’ in climb
below 1000’ in descend
TCAS self-test takes…
20 sec
ATR72-500 SHP…
2750
2450 on T/O
MRM…
22970 kg
MZFM…
20800 kg
MTM…
22800 kg
MLM…
22350 kg
Max range…
890 NM
Ceiling…
25000’
Wing span…
27,05 m
Danger areas…
22/27m behind
Left pack supplies…
Flight deck & cabin
Right pack supplies…
Cabin only
Pack flow
22 psi 30 psi (hotel-mode)
Pack heat exchangers are cooled by…
Ram air above 150 kts
Cooling fans below 150 kts
Aircondition overheat caution…
T > 274c
controlled by MFC
Aircondition leak caution…
Tloop > 153c
Airconduct temp high…
If above 88c: Hot air valve closes
If above 92c: Warning on CCAS and no aut action
Pack valve closes automatically if…
downstream temp from compressor reaches 204c
Max differential cabin pressure…
+6.35 psi, guarded by manometric valve
Manual mode cabin rate of change…
Cabin pressure
+ 2500 ft/min
- 1500 ft/min
Cabin descend rate…
Pressurization
Norm: - 400 ft/min
Fast: - 500 ft/min
Altitude alert…
AFCS
- 1000 ft from selected altitude
- 250 ft from selected altitude
High bank/low bank…
AFCS
27/15 degrees bank
Proximate traffic…
TCAS
+/- 850ft and 6nm out
Stickpusher is inhibited…
- On ground
- 10 sec after T/O
- below 500’ during descend
T/O inhibit pb…
CCAS
All amber light except;
- EFIS COMP
- PRKG BRK
- GPWS
- MAIN PNL
- ENG
VFE flaps 15
185 kts
VFE flaps 30
145 kts
VLE
180 kts
VMO
250 kts
Starter/generator nominal voltage…
27-31 volt DC
Norm: 30v
Starter/generator output…
12 KW @ 400 A
Warnings not process by MFC…
ENG FIRE EXCESS CAB P EXCESS CAB ALT NAC OVHT SMOKE
Air bleed LEAK…
T loop > 153c
Air bleed OVHT…
Bleed duct T > 274c
Not to confuse with PACK OVHT 204c
PACK valve functions
Pack shut off
Pressure control
PACK cooling fans start…
IAS < 150 kts gear DN
IAS < 150 kts gear UP + 10 min
ENG OIL LOW PRESS opposite side
DUCT temp > 88c ?
aircondition
Hot air bypass valve closes
Aircondition OVHT caution…
duct temp > 92c
PACK remain open
Overheat condition downstream PACK compressor?
PACK closes at T > 204c
Not to confuse with BLEED OVHT 274c
For passanger comfort; right PACK has a delay of…
6 seconds
PACK flow… (PSI)
22 psi NORM
30 psi HIGH
High/low bank select PB…
AFCS
Low 15 degrees
High 27 degrees
Annunciated on ADU
TCS resyncronization limits…
AFCS
Pitch 15 degrees up
Roll 6 - 35 degrees
Below 6 ; AP roll wings level
1.04.10
During ILS approach…
AFCS
DUAL CPL if both NAV set to ILS
Emergency light has ____ capacity and powered by ____ v integral battery
10 min; 6 volt
Emergency light ARM switch, the emergency lights illuminate when…
DC bus voltage is below 18v or dual GEN loss