(F)Element 8-47 Equipment Faults-4 Flashcards

1
Q

If the magnetron is allowed to operate without the magnetic field in place:

A

It will quickly destroy itself from excessive current flow.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Targets displayed on the RADAR display are not on the same bearing as their visual bearing. What should you first suspect?

A

Incorrect antenna position information.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Loss of distant targets during and immediately after wet weather indicates

A

A leak in waveguide or rotary joint.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In a marine RADAR set, a high VSWR is indicated at the magnetron output. The waveguide and rotary joint appear to be functioning properly. What component may be malfunctioning?

A

The waveguide array termination

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

On a vessel with two RADARs, one has a different range indication on a specific target than the other. How would you determine which RADAR is incorrect?

A

Check the sweep and timing circuits of both indicators for correct readings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

An increase in the deflection on the magnetron current meter could likely be caused by:

A

A decrease of the magnetic field strength.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly