Extras Flashcards

1
Q

_______coal is a coal that is ground into a fine powder

A

Pulverized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

_______coal is a hard coal with a high luster that yields a small amount of volatile matter when is burned

A

Anthracite

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

_______coal is a soft coal that yields a large amount of volatile when is burns

A

Bituminous

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The_____is the full lengh of a coal stoker

A

Retort

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A______draft fan is a fan located before the furnace that supplies the necessary air and air flow for the combustion proces

A

Forced

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

______is the burning of fuel on a grate at a rate that only sustain the ignition

A

Banking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The______is the location in a coal stoker where the coal is burned

A

Moving grate zone

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The_____is the location in a coal stoker where any remaining coal is burned before discharging to the ash pit

A

Dumping grate zone

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A_______control is a control that regulates fuel supply, air supply, air-to-fuel ratio and removal of gases of combustion in a boiler

A

Combustion control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

_______is the amount of fuel the burner is capable of burning in a giving unit of time

A

Firing rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

An______is an air pressure-actuated switch that closes after proving sufficient pressure of combustion air from the forced draft

A

Air proving switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

_____is the condition where a flame teavels upwind and into the burner assambly

A

Flashback

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A______is a control that functions as the mastermind of the burner control system to control the firing cycle

A

Programmer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

_____is the period of time after startup

A

Prepurge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

_______is the period of time during which the pilot and main burner must be ignited

A

Ignition trials

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The pilot_______period is the period during which the programmer permits the pilot valve to be open and the flame detector is required to detect the pilot flame

A

Flame-establishing

17
Q

A______is a safety device that senses if the pilot light and/or main flame are lit

A

Flame scanner

18
Q

A_____is the sensing device in a flame scanner used to sense the pilot and main flame in the burner

A

Flame sensor

19
Q

A_____is a flame sensor that senses visible light from the burner

A

Photocell sensor

20
Q

_________is a flame sensor that senses light frequencies that are higher than those to the eye

A

Ultraviolet sensor

21
Q

An______is a flame sensor that senses light frequencies that are lower than those visible to the eye

A

Infrared sensor

22
Q

______ _____is the ability of a burner to burn fuel as indicated by the amount of unburned fuel and excess air in the gases of combustion

A

Combustion efficiency