ESWS MCM CLASS STUDYGUIDES Flashcards
Where is unit 50 located?
Located in Sonar Maintenance.
What is Unit 50 use for?
It is use to raise and lower the towed body.
Describe the stations of the AN/SQQ-32 (V)4?
The Classify and Detect stations of the AN/SQQ-32 (V)4 are interchangeable.
What is the Swath Degree of the AN/SQQ (V)4?
The Swath Degree of the AN/SQQ-32 (V)4 is 180 degrees.
What are the risks directives?
ALPHA is CREW FIRST
BRAVO is 50/50
CHARLIE is Mission First and safety of the Crew Second
Where is Unit 50 connected?
Unit 50 is a box connected to Unit 3.
Where is AN/SLQ-48 located?
AN/SLQ-48 Unit 1 is on the Port side and Unit 2 is on the Starboard side.
Describe Unit 1 of the AN/SLQ-48.
The upper portion of Unit 1 is the Acoustic Transmit Panel. The Acoustic Transmit Panel has a alpha numeric code that is sent via the WQC-Z
Where is the control panel of the WCN-1 located?
The control panel for the WCN-1 is located above Unit 7.
What are the emergency recovery buttons on the AN/SLQ-48?
The emergency recovery buttons on the AN/SLQ-48 are JTSN BALST, EMERGENCY RECOVERY, CUT UMBILICAL and JETISON CHARGE.
What are the responsibilities of the monitor on the AN/SLQ-48?
The responsibilities of the monitor on the AN/SLQ-48 are to guide the pilot in utilizing sonar and monitor performance of the MNV.
What is the range of the sonar on the MNV?
The range of the sonar on the MNV is 3 to 300 yards.
What is the max speed of the MNV?
The MNV max speed is 6 knots.
What is one of the limitation of MNV?
The MNV cannot operate in sea state over 3 or current over 3.
What part of the UCHS steps up the voltage to 2500v?
The part of the UCHS that steps up the voltage to 2500v is the HIGH VOLTAGE TRANSFORMER located in 400Hz