ESWS DC Flashcards
Who is the DCTT Leader?
XO
Who are the first responders to a casualty underway
Flying Squad
Rapid Response teams job
Go straight to scene and take appropriate actions
how many personnel are assigned to the Rapid Response Team
4
Who are the members of the Rapid Response Team
Fire Marshal
Electrician
2 Investigators/Boundary Men
What is the responsibility of the Rescue and Assistance team
Back up to the at sea fire party and assist other ships in distress
What NSTM can you find information about surface ship fire fighting
NSTM 555
If you needed to validate fittings on your CCOL where would you look?
Dc books
What book contains step by step procedures for handling casualties?
Repair party Manual(RPM)
What book is used for combating fires in Main Spaces?
Main Space Fire Doctrine
If you need to keep a fitting open for an extended period of time what do you do?
Log it in the Material Conditions Violation section of the Closure log
How long can you keep it open?
Not longer then 24 hours
Fittings you cannot secure are logged where?
OOC log (Out of Commission log)
Who maintains the closure log
EWS inport DCWS underway
Who reviews the closure log?
FM, DUTY FM, ADCA, DCA, EDO
Name one side of the fire tetrahedron?
Oxygen, Fuel, Heal, uninhibited chain reaction
Describe Classes of Fire
A(Leaves Ashes) B (HAZMAT,Fuel) C (electrical) D (Combustible metals)
What is the flashpoint of JP-5
140 Degrees
4 Stages of fire?
Growth, Flashover, Fully developed and Decay
How many repair lockers do we have?
10
Name repair lockers?
2ND deck (2,3,4,5) 1st Deck(1F,1B,1A) 03 (7F,7B,7A)
Which repair lockers respond to main space fires?
Repair 4-5
What do you use to inventory the kits in repair lockers?
AEL allowance equipage list
PKP comes in 2 sizes, what are they?
18, 27
PKP?
Potassium bicarbonate
What is effective range of a CO2 extinguisher
4-6 feet
In continuous operation, how long does the 15-pound CO2 extinguisher last?
40 seconds
Before you squeeze the lever to release the CO2, What should you do?
Ground the cylinder to the deck, Avoid static shock
How does CO2 extinguish a fire?
It reduces the concentration of oxygen in the air to the point where combustion stops.
What are the portable AFFF bottles used for?
Small grease and small class ‘B’ fires
What is the distance of a portable AFFF bottle?
15 ft and decreases with use
How much AFFF is in the bottle?
2 Gallons
What are the best woods to use for shoring, plugs and wedges?
Douglas fur and yellow pine
why do we use this type of wood?
it expands as it absorbs water
2 sizes of metal shores?
3-5 feet 6-11 feet
What is the vertical load strength of a 3 foot to 5 foot metal shore?
3 ft - 20,000 Lb , 5 ft - 12,000
What is the vertical load strength of a 6-11 ft metal shore?
6 ft 20,000 lb , 11 ft - 6000 lb
Name 3 types of shoring
I(Direct Pressure), K (Triangulation perpendicular), H (no deck anchorage)
What is the strongest shoring?
I type
What is the weakest shoring?
H type
How many types of pipe patches are there?
4
What are the type of pipe patches?
Soft, Banding, Ewarp, Jubilee
Which hold up to 100 PSI only?
Jubilee
What is the max temperature on a pipe you can apply EWARP?
300 Degrees
What is the Max PSI for Banding, Soft, Ewarp
150 PSI
What does NIFTI stand for?
Naval Firefighting Thermal Imager
What powers the Nifti?
10 AA batteries
Is the NIMH battery pack rechargable?
yes
How do you know the NIFTI is fully charged
10 bars on the bottom left corner
Name 5 kits found in a repair locker?
Investigator Electrician Comms Pipe patching Shoring
what does PECU stand for?
Portable Exothermic Cutting Unit
Where are they located?
Repair lockers
Who operates them?
Access/Overhaul person
What are the cutting rods of PECU made of?
Carbon Steel
What size of battery does the PECU use?
12 volt
What are the two types of portable eductors?
Stype and Peri jet
What is the primary use of eductors?
to remove Greasy, Oily and contaminated water
What is primary use of the P-100?
firefighting/dewatering
How many P-100 onboard?
2
Where are they?
HB1 STBD side MOORING RM
HB2 ADML Pway under the ladder
What cools the P-100 while its being used?
AIR
What is the maximum lift that a P-100 pump can take suction?
20 Feet
What type of fuel does the P-100 use?
JP-5
ESP?
Electrical submersible Pump
Submersible pumps are not designed for pumping what types of liquids?
Gasoline, Heavy Oils, or hot water
What is the maximum static head for the ESP?
70’
When using EPS in tandem, which pump do you start first?
The bottom one
Ram Fan?
De smoke spaces containing explosive gases
What powers the RAM fan?
Fire main
what safety precautions must be followed prior to energizing the ram fan?
Ground it
What maximum number of trunks can you put on the suction side?
3
Ram fan hoses on the suction side how are they connected?
Latching clamps on the ends of the trunks
How many cubic feet per minute will it move?
2000
Where can you use the Box Fan for desmoking operations?
spaces adjacent to weatherdeck/hanger bay areas
what powers the box fan?
Electricity
how much air will it move?
3200 CFM
Who is in charge of a repair locker during a casualty?
locker leader
who is responsible for handling electrical damage?
repair electrician
Who is overall in charge of a casualty inside the effected space?
team leader
Who caries the NFTI?
Team leader
How long will the OCENCO EEBD last during use?
10 minutes
Who wears a 30 minute bottle/45 minute SCBA pack?
30 Investigator, Boundary men, Scene leader
45 team leader and hose team
What percent of air do you have left on your scba when the vibra-alert goes off?
25%
what are the 2 types of alarms on the SCBA when your air is low?
bell and the vibrant alarm
What are the SCBA bottles Made of?
Carbon Fiber
What should you do once you take out an SCBA pack prior ot use?
Ensure that it is not below 4000 PSI
The nozzle has 3 positions on it what are they?
Solid stream(Over haul), High velocity(Fire fighting), Low velocity(cooling and relief) and flush.
Which boundary should be set the fastest during a fire?
Above
Who determines a space is safe to enter without breathing protection after a fire?
DCA(at sea)/EDO inport
What person on the fire party conducts atmospheric testing?
Fire marshal/ Gas Free Engineer
What are the four principles of investigation?
thoroughly, cautiously, report, repeat
Air sucking in the test fitting indicates what kind of damage?
fire
Air escaping the test fitting indicates what kind of damage?
flooding
APC stands for?
Aqueous Potassium Carbonate
What is the APC system used for?
Protection for galley deep fat and doughnut fryers and their exhaust system
How does APC extinguish a fire?
Combines with the hot cooking oil to cut the oxygen out
Where can you find APC?
Galley
How many halon boards do we have?
9
What activates the halon board
fully pull the activation lever on the 5lb c02 bottle
what does 30 sec time delay mean?
unmanned space
Name on space where we have a halon board?
FWD/AFT EDG, Pump room 2 and 3, Shaft alley
Lights on board Halon
White : power avaiable
Amber : Halon Activated
Red : Halon discharge
Green : vent damper
How many C02 fixed flooding systems do we have?
4
How do you activate c02 fix flooding?
Break glass pull T shaped handle until you see red on cable
Name one space the CO2 fix flooding can be found?
Hazmat storerooms
How many recharge stations do we have?
8
Name one recharge station?
1b(2), 1A, 1F, 2, 3, 7B, 7F
If we lose HP air, what do we use to fill the SCBA bottles?
EBAC (Emergency breathing air compressor)
How many EBAC’s do we have?
2
Name the location of one?
1 forward STBD side, 2nd aft next to the jet shop
what is the purpose of list control?
To correct list, so planes can land
How many list control tanks do we have?
10
How many list control pumps?
2
How many places can you operate list control?
2 MCMS in DCC and locally in 4a shaft alley
What type of water is in the list control tanks?
Potable water
where are the list control pumps located?
4A shaft alley
What is the GPM for list control pumps
1800 GPM
who operates list control
DCWS
What 2 list control tanks can hold the most?
113&165
What do we use to determine the list?
Clinometer
What type of firemain do we have?
Composite loop
How many fire pumps do we have?
23 19 electrical, 4 steam
If there is a rupture in the firemain how do you keep it active in that section of the loop?
Rig a 2 1/2 “jumper hose between the 2 closest fire stations by removing the y gate
How many drainage eductors do we have?
13
How do you operate the drainage system to pump over the side
discharge valve, firemain valve, suction valve
how do you secure the drainage system over the side?
suction valve, firemain valve, discharge valve
What is the purpose of main drainage?
Pump oil waste or water out of the bilges
How many HICAP AFF stations do we have?
20
collectively, where are they located?
2nd deck
How many mixing stations do we have?
21
Where are they located?
on the 03 level
What so special about 21?
bomb farm
What are the tanks made of?
90/10 copper nickle alloy
how much AFFF is in the tanks?
600 gallons
how many AFFF stations have balance pumps?
16
how many AFFF have injection pumps?
20
which stations are injection pump only?
1,2,11,12
What is the mixing ration for Firemain and AFFF?
94%, 6%
What is the GPM for the injection pump?
60 GPM
What is the GPM for the BPP?
65 GPM
What is the pancake valve?
Regulates AFFF & Firemain
what must you have to ensure the AFFF station will operate?
firemain pressure
What is the minimum to maximum firemain pressure needed for AFFF?
125-170
SOPV
Energize the Station Solinode operate pilot valve
How many volts in the SOPV?
440V
How many reserve tanks do we have?
2
How much AFFF concentrate is in the transfer tank?
3600 gallons
Location of AFFF reserve tanks
HB1 PORT HB3 STBD
Reserve pump locations?
6,13
What is the GPM for the reserve pumps?
360 gpm
How can you activate the reserve station?
remotely and locally
Where can it be activated from?
Bridge panel, Pri fly Panel, Hose reels in the catwalks, Hanger bay sprinklers, Hose reels in the hangar bay, Weapons Elecators, Main Space hose reels, 2nd deck hose reels, Bilge and over head sprinklers
How many sound powered phone circuits are there?
5
What circuit links DC central to Repair lockers
2JZ
Primary use of communication from the locker to the scene?
Hydra
What is used to keep a hard copy record of events of a casualty
Message blanks and DC charts
How do we plot damage?
DCAMS and Dc charts
What does a circle on a message blank mean?
casualty contained
What is MPE?
Maximum permissible exposure
Who sets MPE?
CO
What does MOPP stand for?
Mission Oriented Protective Posture
What is the primary protection during Chemical, Biological and Radiological attack?
MCU-2P Gas Mask
What type of threads does the C-2 canister have?
NATO
What does ACPG stand for?
Advance Chemical Protective Garment
Don/Doff
Don put on Doff Remove
Remove ACPG smock?
Stage 1
what stage do you remove gloves and liners?
Stage 3
What is the purpose of the M-256a1 kit?
Used to detect Nerve, Blood, Blister in vapor form?
What does RSDL stand for?
Reactive Skin Decontamination lotion
Waht is RSDL for?
Decontaminate area of the skin
The kit contains how many pouches and what color are they?
- color is green. blue is for training
How long must RSDL remain on the skin after applied?
2 Minutes
What color does M-9 paper turn when agent is present?
Red
At what MOPP level is M-8 paper posted?
Mopp level 2
How many MOPP levels?
5
What MOPP level are we we at right now?
1
MOPP levels?
0,1,2,3,4
IPDS?
Improved Point Detection System
CDU
Control Display Unit in central
RDU?
Remoate display unit bridge
Difference between CDU and RDU?
Bridge doesn’t have controls just the one in central
what type of system is IPDS?
FIxed
What does it detect?
Nerve (g and H) series and blister
What is HTH
High test hypochlorite
How many CCA’s do we have?
2 (HB1,HB3)
How many DS do we have?
4, Forward by REP2 Male berthing, 2 midship (Male weapons berthing, Female Chiefs Head) 1 AFT Reactor Male berthing
Repair 7F
03-10-2-Q
Repair 7B
03 ATO SHACK
Repair 7A
03-220-9Q
Repair 1F
1-69-2-Q
Repair 1B
1-143-2-Q
Repair 1A
1-225-5-Q
Repair 2
2-34-2-Q
Repair 4
2-99-2-Q
Repair 5
2-160-2-Q
Repair 3
2-220-9-Q