Estimation Of Iron In An Iron Tablet Flashcards

1
Q

Why do you need to standardise something?

A

To find conc.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Why was it necessary to standardise the potassium manganate solution immediately before use in the titration?

A

Unstable and affected by light

Decomposes in presence of heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What reagent is used to standardise potassium manganate immediately before use?

A

Ammonium iron II sulfate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Explain why additional dilute sulfuric acid must be added to the titration flask before each titration is carried out

A

To ensure complete conversion of MnO4- to Mn2+

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Why is some dilute sulfuric acid used to make the 250cm3 solution?

A

To prevent the oxidation by air of Fe2+

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What’s the colour change?

A

Colourless to pink

How well did you know this?
1
Not at all
2
3
4
5
Perfectly