ERP ADD4 Ultraradiac Personal Radiation Monitor Flashcards

1
Q

What type of radiation can the UltraRadiac detect?

A

Gamma and X-ray

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How shall the Ultraradiac be secured to the Officer’s gear?

A

Continuously secured to Officer’s H/T by the use of the UR Retention strap.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When are Fire Officers required to wear and have their designated Ultra Radiacs turned on?

A

Whenever they are out of quarters.

emergency and non-emergency responses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When shall Fire Officers ensure their UR’s are tested and accumulated doses are cleared?

a) daily
b) tourly
c) after each response

A

b) AT THE BEGINNING OF EACH TOUR.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

T OR F

Officers shall ensure that their designated UR’s are turned off when in quarters.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where are the UltraRadiacs designated for FF use stored?

a) in quarters
b) in the crew cab in an accessible location
c) a secure location on the fire apparatus
d) near the Officer

A

c) secure location on the fire apparatus.

* in a YELLOW pelican case.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Whenever UR’s designated for use by firemen are required to be worn, what are the two methods of securing them?

A

1) secured to each FF H/T case with the Ultraradiac retention strap
2) secured to the bunker coat by the UR case.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When are operational tests done and doses cleared if FF are required to wear their UR?

A

Prior to operating at radiological incidents OR when ordered by the IC.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

To check your stay time at a Biological incident, a member should press which button on the UR?

A

ALARM button.

Will tell you the number of minutes you can stay in the area without exceeding the High Dose threshold.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How do you test the UR to make sure it is properly functioning?
How will you know it is functioning properly?

A
  • -Hold down the “CLR/TEST” button until display test sequence begins.
  • -A blinking “9” indicates UR PASSED all tests.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What indicated an instrument failure?

What should be done in this case?

A

A blinking “0” indicates failure.

Place Ultraradiac OOS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How would a member using the UltraRadiac clear their dose?

A

1) Press “DOSE”.
2) Press and hold “DOSE” and “CLR/TEST keys at the same time.
3) Display will flash for a few seconds then clear the accumulated dose.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the Source Finder Mode?

How does it alert a member to radioactive materials?

A

Allows a unit to locate an isolated source by using an audible sound. The unit will start clicking if near radioactive material. As the unit moves closer it will click faster.
AIM TOP OF UNIT AT SUSPECTED SOURCE OF RADIATION

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How do you place the UR in Source Finder Mode?

A

Hold the “RATE” key until display changes to “1”. release “Rate” key

to disable: Hold Rate key until “0” comes up, then release.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the Low Rate Alarm for the Ultra Radiac and how is it displayed?

A

2mR/hr

  • visual rate/alarm indicators will flash slowly
  • audio alarm will beep slowly
  • GREEN light on LEFT side will flash slowly
  • the UR will vibrate slowly
  • *c/r ERP 2 mR/hr is where the Hotline is established at bio incidents.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When will the High Rate Alarm flash?

A
  • 50 R/hr
  • audio alarm will beep quickly
  • RED light on LEFT side flashes quickly
  • UR will vibrate quickly
17
Q

Whats the Low Dose Alarm?

High Dose Alarm?

A
low= 5 R
high= 12R

*audio, visual alarms are the same as low/high Rate.

18
Q

Return OOS UltraRadiacs with case to_________for exchange and Repair.

A

Haz Mat Operations

19
Q

True or False

To mark the Ultra Radiac case, the units designation should be written in 1” black marker on the front flap.

A

FALSE

*UltraRadiac cases shall not be permanently marked with any type of unit designation.

20
Q

Where are the UltraRadiacs designated for FF use stored?

a) in quarters
b) in the crew cab in an accessible location
c) a secure location on the fire apparatus
d) near the Officer

A

c) secure location on the fire apparatus In a YELLOW pelican case.

21
Q

A blinking “b” indicates what?

A

Unit has stopped functioning, batteries need to be replaced.

22
Q

Blinking “BAT” is seen in the topl left corner indicates_______?

A

10 hrs of usefull life left in batteries. They need to be replaced

23
Q

Four AAA batteries provide ____hrs of continuous monitoring

A

150 hrs

24
Q

In the Rate mode with the “BAT” blinking indicator, press the CLR/TEST key to get a 3 digit number which will indicate what?

A

Approximate remaining battery life, in minutes.

25
Q

How often should the UltraRadiac be checked, including an operational test and cleaning of its surface with a clean soft cloth?

A

WEEKLY

26
Q

If a high Does (12R) Alarm goes off, the flashing Red light and DOSE/ALARM indicators can be turned off by clearing the accumulated does? When cab this be done at a radiological incident or emergency?

A

Until the accumulated does is recorded OR
When ordered by the IC.

*Same For a Low Dose Alarm (5 R)