Equipment Flashcards
Mortbeam startup procedure
- Elevate mortbeam in air
- Turn on, wait for self-check
- Scn arm or leg to check for correct operation
- Lower the probe to the ground.
Mortbeam Optimum distance
20mm
Mortbeam Wire depth + Min wire length
50mm depth
Minimum 2-5m Length
Mortbeam Battery info
8 Hour life
Alkaline will show low battery 30 minute warning
Lithium will power down with no warning
Hoodlum Battery info
1 x 9V Battery
50 Hours battery Mk1
40 Hours battery Mk2
Hoodlum Detection depths
200mm on Pistol
70mm on 2 pence piece
65mm on detonator
50mm when pinpointing
Grudge Battery Info
4 x C Cell batteries
12 Hour Battery life
Grudge Depth detection
177mm on 2 pence piece
Grudge Zeroing info
Zero every 60 seconds minimum
When pinpointing every 30 seconds minimum
Vallon Battery info
3 x D cell batteries
18-25 Hour battery life
Vallon detection depths
Large metallic AV Mines - 300mm
Small metallic AP Mines - 150mm
Maximum detection depth - 1.5m
Goldie Battery Info
4 x AA Batteries
6 Hours non-lithium batteries
8 Hour Lithium batteries
Low battery alarm every 1.5 seconds
Goldie Detection Info
500mm detection depth Minimum cable length 50m Green light - 50m cable Amber light - 100m cable Red light - unknown length of cable
Goldie ZERO info
Zero every 60 seconds or everytime you stop
FEREX Battery Info
4 x D Cell batteries