TYPE OF ENGINES?
Twin Detroit Diesel Series 60 engines with DDEC IV
TYPE OF WATER JETS?
Twin Kamewa FF3755 Waterjets
TYPE OF REDUSTION GEARS?
Twin Disc MG5114SC Reduction Gears
ENGINE HORSE POWER?
825 HP
FUEL CAPCITY?
510 GALS @ 100% 485 GALS @ 95 % 468 GALS USEABLE
HOT START TYPE?
The Kim Hot Start 1500W
HOT START TEMP?
120* @ 0* F OUTSIDE
SECONDARY FUEL FILTER RATED @?
8 MICRONS
The fuel tank is located between Frames?
3.5 & 10
FUEL SOUNDING ROD IS MARKED IN ____ INCREMENTS….
25 GALS
The Fuel Tank Vent is located?
Starboard side of the boat between Frames 7 and 8.
Type of fuel vent?
Inverted ball check valve
What does the “come home” feature do?
Permits a mechanical lock-up of the clutch
Situations that
may require use of come-home are?
- Loss of hydraulic pump pressure
2. Loss of oil.
Reduction Gear ratio?
1.02 : 1
Sea suction valves location?
Between the Transom and Frame 1 on both sides of the keel in the Lazarette
Sideways movement of the boat is controlled by?
The Steering Nozzle
Full steering locks @?
30 degrees
Type of Trim Tabs?
“Interceptor” Trim Tabs
Interceptor trim tabs are located on the?
lower outboard section of the water jet.
The Hydraulic Tank is located?
In the Engine Room port side between frame 5 and 6.
The hydraulic tank holds______gallons of hydraulic fluid?
9
Transducer is located in the?
Lazarette
The PSEA Ethernet Hub is located in the?
Auxiliary Machinery Compartment on the
aft bulkhead centerline
Electrical power is supplied by?
Two Auragen Power Generation Systems. Belt driven generators.
How many battery banks are there?
2……The Start Battery Bank and The House Battery Bank
What does the START battery provide power to?
provides 24-VDC power for diesel engine starting and 24P2 DC Power Panel
What does the HOUSE battery provide power to?
provides 24-VDC to the 24P1 and 24P3 DC Power Panels.
True or False….The battery
banks operate independent of each other.
True
In the event of an emergency, the battery banks can be?
cross-connected through manual operation of the Automatic Charging Relay.
R/G Oil Pressure (disengaged):
Normal 15-65psi, Disabling 65
R/G Oil Pressure engaged (2300 rpm):
Normal 185-265psi, Disabling 265
R/G Oil Temp
MAX of 193°
Normal Engine Temp:
MAX of 211°
Lube oil pressure @2300RPM
Normal >41psi Disabling <31psi Alarm sounds at 30psi
Bilge Pumps
33GPM x 6
Lube oil pressure @ 650RPM
Normal >10 Disabling <10
Coolant capacity
15 Gallons of Power Cool 50/50 pre-blend
Engine oil capacity
43 quarts of 15W40
Shaft rotation
Left hand rotation (Aft looking fwd)
Block formation
Inline six cylinder (meaning there are six cylinders in a row instead of three on each side)
Jacket water Temp
Normal-140-185F, Restrictive- 186-211, Disabling and Alarm sounds at 212F
Jacket water flow rate
178 GPM
Raw water flow rate
125 GPM
Reduction Gear–Oil Capacity
2.8 Gal. 15W40