Engine Limitations Flashcards
1
Q
Min batt voltage for engine start
A
24V
2
Q
Max transient TRQ
A
115% (10 secs)
3
Q
Max takeoff TRQ
A
111% (5 mins at takeoff)
4
Q
Max continuous TRQ
A
92%
5
Q
Max engine start TOT
A
927°C (10 secs over 810°)
6
Q
Max transient TOT
A
899°C (6 secs over 810°C)
7
Q
Max take off TOT
A
810°C (5 min at T/O)
8
Q
Max continuous TOT
A
752°C
9
Q
Max continuous N2
A
2130
10
Q
Max static ground ops with crosswind >10 kts (N2)
A
1850
11
Q
Max transient N1
A
106% (max 15 seconds >105%)
12
Q
Max continuous N1
A
105%
13
Q
Max transient oil pressure (cold weather / engine start)
A
150psi
14
Q
Max oil pressure
A
130 psi
15
Q
Min oil pressure at N1 >94%
A
120 psi (decreases linearly by 2 psi for every 1000ft above 5000ft pressure altitude to a max reduction of 20 psi)