Emergency Procedures Flashcards
1
Q
Abnormal Start
A
- ) Condition Lever - FUEL CUTOFF (note ITT decrease to below 790C)
- ) Starter - Starter only (for the remainder of the 40 seconds)
- ) Starter - OFF (at 40 seconds)
2
Q
Emergency Shutdown on Deck
A
- ) Condition Levers - FUEL CUTOFF
- ) Firewall valves - CLOSED
- ) Boost pumps - OFF
- ) Fire extinguisher - As Required
- ) AUX BATT Switch - OFF
- ) Gangbar - OFF
- ) Evacuate aircraft
3
Q
Brake Fire
A
- ) Stop Aircraft
- ) Firefighting Assistance - Request
- ) Emergency Shutdown on Deck Checklist - Execute
4
Q
Aborting Takeoff
A
- ) Announce “Abort”
- ) Power levers - IDLE
- ) Reverse - As Required
- ) Brakes - As required
As soon as practicable:
- ) Condition levers - FUEL CUTOFF
- ) Firewall valves - CLOSED
- ) Boost Pumps - OFF
- ) Fire extinguisher(s) - As Required
- ) AUX BATT switch - OFF
- ) Gangbar - OFF
- ) Evacuate aircraft
5
Q
Engine Failure After Takeoff
A
- ) Power - As Required
- ) Gear - UP
- ) Airspeed – As Required (V_XSE or V_YSE)
- ) Emergency Shutdown Checklist - Execute
6
Q
Emergency Shutdown Checklist
A
- ) Power lever - IDLE
- ) Prop lever - FEATHER
- ) Condition lever - FUEL CUTOFF
If prop fails to feather, alternate feathering checklist.
If confirmed/suspected fire or fuel leak, continue steps 4-6.
- ) Firewall valve - CLOSED
- ) Fire Extinguisher - As Required
- ) Bleed air - CLOSED
7
Q
Single-Engine Waveoff/Missed Approach
A
- ) Power - Max Allowable, establish positive rate of climb (V_XSE minimum)
- ) Flaps - APPROACH (unless already UP)
- ) Gear - UP
- ) Flaps - UP
- ) Prop - 1900 RPM
8
Q
Jammed Power Lever
A
- ) Condition Lever (affected engine)- FUEL CUTOFF
2. ) Emergency Shutdown Checklist - Execute
9
Q
Fuel Leaks
A
- ) Condition Lever - FUEL CUTOFF
2. ) Emergency Shutdown Checklist - Execute
10
Q
Primary Governor Failure/Malfunction
A
- ) Attempt to adjust prop RPM to normal operating range
- ) Power Lever - IDLE
- ) Prop Lever - FEATHER
- ) Alternate Prop Feathering Checklist - As Required
11
Q
Generator Failure
A
- ) Starter - OFF
- ) Generator - OFF, Reset Momentarily, release slowly to ON
If generator will not reset:
- ) Generator - OFF
- ) Current limiter ( Battery Ammeter) - Checked
12
Q
Smoke and Fume Elimination
A
- ) Oxygen masks/MIC switches (100 percent) - As Required
2. ) Pressurization - DUMP
13
Q
Explosive Decompression
A
- ) Oxygen masks/MIC switches (100 percent) - As Required
2. ) Descend - As Required
14
Q
Smoke/Fire of Unknown Origin
A
- ) Crew - Alerted
- ) Cabin temperature mode - OFF
- ) Vent blower - AUTO
- ) Oxygen masks/MIC switches (100 percent) - As Required
15
Q
Emergency Descent Procedure
A
- ) Power Levers - IDLE
- ) Props - Full Forward
- ) Flaps - As Required
- ) Landing Gear - As Required
- ) Airspeed - As Required
- ) Windshield Heat - As Required