Emergency Procedures Flashcards
Abnormal Start
- ) Condition Lever - FUEL CUTOFF (note ITT decrease to below 790C)
- ) Starter - Starter only (for the remainder of the 40 seconds)
- ) Starter - OFF (at 40 seconds)
Emergency Shutdown on Deck
- ) Condition Levers - FUEL CUTOFF
- ) Firewall valves - CLOSED
- ) Boost pumps - OFF
- ) Fire extinguisher - As Required
- ) AUX BATT Switch - OFF
- ) Gangbar - OFF
- ) Evacuate aircraft
Brake Fire
- ) Stop Aircraft
- ) Firefighting Assistance - Request
- ) Emergency Shutdown on Deck Checklist - Execute
Aborting Takeoff
- ) Announce “Abort”
- ) Power levers - IDLE
- ) Reverse - As Required
- ) Brakes - As required
As soon as practicable:
- ) Condition levers - FUEL CUTOFF
- ) Firewall valves - CLOSED
- ) Boost Pumps - OFF
- ) Fire extinguisher(s) - As Required
- ) AUX BATT switch - OFF
- ) Gangbar - OFF
- ) Evacuate aircraft
Engine Failure After Takeoff
- ) Power - As Required
- ) Gear - UP
- ) Airspeed – As Required (V_XSE or V_YSE)
- ) Emergency Shutdown Checklist - Execute
Emergency Shutdown Checklist
- ) Power lever - IDLE
- ) Prop lever - FEATHER
- ) Condition lever - FUEL CUTOFF
If prop fails to feather, alternate feathering checklist.
If confirmed/suspected fire or fuel leak, continue steps 4-6.
- ) Firewall valve - CLOSED
- ) Fire Extinguisher - As Required
- ) Bleed air - CLOSED
Single-Engine Waveoff/Missed Approach
- ) Power - Max Allowable, establish positive rate of climb (V_XSE minimum)
- ) Flaps - APPROACH (unless already UP)
- ) Gear - UP
- ) Flaps - UP
- ) Prop - 1900 RPM
Jammed Power Lever
- ) Condition Lever (affected engine)- FUEL CUTOFF
2. ) Emergency Shutdown Checklist - Execute
Fuel Leaks
- ) Condition Lever - FUEL CUTOFF
2. ) Emergency Shutdown Checklist - Execute
Primary Governor Failure/Malfunction
- ) Attempt to adjust prop RPM to normal operating range
- ) Power Lever - IDLE
- ) Prop Lever - FEATHER
- ) Alternate Prop Feathering Checklist - As Required
Generator Failure
- ) Starter - OFF
- ) Generator - OFF, Reset Momentarily, release slowly to ON
If generator will not reset:
- ) Generator - OFF
- ) Current limiter ( Battery Ammeter) - Checked
Smoke and Fume Elimination
- ) Oxygen masks/MIC switches (100 percent) - As Required
2. ) Pressurization - DUMP
Explosive Decompression
- ) Oxygen masks/MIC switches (100 percent) - As Required
2. ) Descend - As Required
Smoke/Fire of Unknown Origin
- ) Crew - Alerted
- ) Cabin temperature mode - OFF
- ) Vent blower - AUTO
- ) Oxygen masks/MIC switches (100 percent) - As Required
Emergency Descent Procedure
- ) Power Levers - IDLE
- ) Props - Full Forward
- ) Flaps - As Required
- ) Landing Gear - As Required
- ) Airspeed - As Required
- ) Windshield Heat - As Required
EGPWS Pull Up Warning (IMC or at Night)
- ) Wings - Level
- ) Power - Max Allowable
- ) Pitch - As required to set and maintain Vx
- ) Flaps - Approach (unless already UP)
- ) Gear - UP
- ) Flaps - UP
- ) Props - 1900 RPM
- ) Continue climb as Vx until all visual and voice warnings cease
Low Altitude Windshear
- ) Power - Maximum Allowable
- ) Attitude - Set and Hold Approximately 15° Noseup
- ) Gear - UP
- ) Flaps - Maintain current setting
Spin/Out Of Control Flight Recovery
- ) Power Levers - Idle
- ) Rudder - Full deflection opposite direction of turn needle
- ) Control Wheel - Rapidly Forward
- ) Rudder - Neutralize after rotation stops
- ) Control Wheel - Pull out of dive by exerting smooth, steady, back pressure
Windmilling Airstart
- ) Power Lever (Failed Engine) - IDLE
- ) Prop Lever (Failed Engine) - Full Forward
- ) Condition Lever (Failed Engine) - FUEL CUTOFF
- ) Firewall valve - OPEN
- ) Autoignition - ARMED
- ) Condition Lever - LOW IDLE
- ) Power - As Required