Emergency procedures Flashcards
EMERGENCY SHUTDOWN ON DECK
*1. CONDITION LEVER(S) - FUEL CUTOFF IN CASE OF CONFIRMED/SUSPECTED FIRE OR FUEL LEAK, CONTINUE CHECKLIST. IF NOT, SECURE REMAINING ENGINE USING SECURE CHECKLIST. *2. FIREWALL VALVES - CLOSED *3. BOOST PUMPS - OFF *4. FIRE EXTINGUISHER - AS REQUIRED *5. AUX BATT SWITCH - OFF *6. GANGBAR - OFF *7. EVACUATE AIRCRAFT
ABNORMAL START
- CONDITION LEVER - FUEL CUTOFF (note dec. below 790°C)
- STARTER - STARTER ONLY (for the remainder of the 40 sec)
- STARTER - OFF (at 40 sec)
ABORTING TAKEOFF
- ANNOUNCE “ABORT”
- POWER LEVERS - IDLE
- REVERSE - AS REQUIRED
- BRAKES - AS REQUIRED
- CONDITION LEVERS - FUEL CUTOFF
- FIREWALL VALVES - CLOSED
- BOOST PUMPS - OFF
- FIRE EXTINGUISHER(S) - AS REQUIRED
- AUX BATT SWITCH - OFF
- GANG BAR - OFF
- EVACUATE AIRCRAFT
ENGINE FAILURE AFTER TAKEOFF
- POWER - AS REQUIRED
- GEAR - UP
- AIRSPEED - AS REQUIRED (Vxse or Vyse)
- EMERGENCY SHUTDOWN CHECKLIST - EXECUTE
EGPWS PULL UP WARNING (IMC OR NIGHT)
- WINGS - LEVEL
- POWER - MAX ALLOWABLE
- PITCH - AS REQUIRED TO SET AND MAINTAIN Vx
- FLAPS - APPROACH (unless already up)
- GEAR - UP
- FLAPS - UP
- PROPS - 1900 RPM
- CONTINUE CLIMB AT Vx UNTIL ALL VISUAL AND VOICE WARNINGS CEASE
LOW ALTITUDE WINDSHEAR
- POWER - MAXIMUM ALLOWABLE
- ATTITUDE - SET AND HOLD APPROXIMATELY 15° NOSE UP
- GEAR - UP
- FLAPS - MAINTAIN CURRENT SETTING
SPIN/OUT OF CONTROL FLIGHT RECOVERY
- POWER LEVERS - IDLE
- RUDDER - FULL DEFLECTION OPPOSITE DIRECTION OF TURN NEEDLE
- CONTROL WHEEL - RAPIDLY FORWARD
- RUDDER - NEUTRALIZE AFTER ROTATION STOPS
- CONTROL WHEEL - PULL OUT OF DIVE BY EXERTING SMOOTH, STEADY BACK PRESSURE
WINDMILLING AIRSTART
+1. POWER LEVER (FAILED ENGINE) - IDLE
+2. PROP LEVER (FAILED ENGINE) - FULL FORWARD
+*3. CONDITION LEVER (FAILED ENGINE) - FUEL CUTOFF
*4. FIREWALL VALVE - OPEN
*5. AUTOIGNITION - ARMED
*6. CONDITION LEVER - LOW IDLE
*7. POWER - AS REQUIRED
EMERGENCY SHUTDOWN CHECKLIST
+1. POWER LEVER - IDLE
+2. PROP LEVER - FEATHER
+*3. CONDITION LEVER - FUEL CUTOFF
If prop fails to feather, alternate feathering checklist. If confirmed/suspected fire or fuel leak, continue steps 4-6.
+4. FIREWALL VALVE - CLOSED
+5. FIRE EXTINGUISHER - AS REQUIRED
+*6. BLEED AIR - CLOSED
SINGLE-ENGINE WAVEOFF/MISSED APPROACH
- POWER - MAX ALLOWABLE, establish positive rate of climb (Vxse minimum)
- FLAPS - APPROACH (unless already up)
- GEAR - UP
- FLAPS - UP
- PROP - 1900 RPM
JAMMED POWER LEVER
+*1. CONDITION LEVER - FUEL CUTOFF
*2. EMERGENCY SHUTDOWN CHECKLIST - EXECUTE
FUEL LEAKS
+*1. CONDITION LEVER - FUEL CUTOFF
*2. EMERGENCY SHUTDOWN CHECKLIST - EXECUTE
PRIMARY GOVERNOR FAILURE/MALFUNCTION
1. ATTEMPT TO ADJUST RPM TO NORMAL OPERATING RANGE
+2. POWER LEVER - IDLE
+*3. PROP LEVER - FEATHER
*4. ALTERNATE PROP FEATHERING CHECKLIST - AS REQUIRED
GENERATOR FAILURE
*1. GENERATOR - OFF, RESET MOMENTARILY, THEN ON
If generator will not reset:
- GENERATOR - OFF
- CURRENT LIMITER (battery ammeter) - CHECKED
SMOKE AND FUME ELIMINATION
- OXYGEN MASKS/MIC SWITCHES (100%) - AS REQUIRED
* 2. PRESSURIZATION - DUMP