What is natural gas comprised of?
Mainly of methane but also contains propane, ethane and nitrogen
What classification Haz Mat is natural gas?
Class too, division one substance. Extremely flammable
Depending on the mixture, the explosive range is
5 to 15%
Colorless and odorless; however to aid in detection ______ is added to natural gas as an odorant giving it a____ smell.
Mercaptan; rotting
Mercaptan can be masked by other orders, stripped by chemicals or removed as natural gas passes through material such as soil. In addition, members operating in a gas environment can become desensitized to the smell
Is natural gas lighter than air?
Significantly lighter than air
Is natural gas toxic?
Non-toxic, but insufficient quantity natural gas can displace oxygen in and close space and cause asphyxiation
2 ft.³ of natural gas has the approximate energy potential of____ of tnt
1 pound
When unconfined outdoors, can natural gas explode?
It will burn rapidly without triggering explosive pressure
Where are con Edison gas distributes?
Manhattan, the Bronx, and in Queens, generally north of the Grand Central Parkway
National grid distribute gas to?
Brooklyn, Staten Island and in Queens, generally south of the Grand Central Parkway
Gate stations are facilities that have remote monitoring by the utility company gas control center. Do they have on-site personnel?
Generally have no permanent on site personnel. Any event in these facilities should be considered an industrial facility emergency and actions should be limited to life saving and protecting exposures until the utility company has been consulted
Natural gas is piped to customers a long distribution mains which may be high, medium or low pressure. High pressure distribution means are made of?
Steel, and I generally installed below major roads
Medium and low pressure distribution means are made of?
Steel, plastic, or if older, cast iron. Cast-iron pipe is currently being replaced as it is prone to corrosion and failure, being brittle with low tensile strength
________Pressure distribution mains have control valves that are exercised partially on a schedule to ensure working order. These valves are generally found near street corners, but may also be located along the street or on the sidewalk. Main valve covers are larger than curb valve/service valve covers to allow servicing and may be round or square
Hi and medium
Which companies gas Main valves have ID numbers on tags inside the valve cover?
Conedison
Which company main valve covers are identified by an ID number stamped on the north side of the collar, underneath the cover;, however, these numbers may be difficult to say
National grid
Which distribution means generally do not have valves and isolating sections?
Low pressure 1/4 psi Distribution means generally do not have valves and isolating sections of low pressure distribution mains requires plugging or squeezing off the pipe while still under pressure. Only the utility company can safely plug or squeeze off distribution or service means due to spark hazards
Curb valve/service valves are usually found on which side of the curb and these valves shut the gas supply to the entire building? They are usually recessed in from the curb and are covered with What size plate?
Sidewalk side.
4” x 4” square or round, brittle concrete or steel cover which may be sitting on top of plastic or wooden plate
Which gas company, has the curb valve/service valve sometimes located across the street from the building at supplies? and may be found in the street. This type of curb valve/service valve can be identified how?
National grid; identified by an arrow cast into the cover pointing to the building and supplies.
Some gas service piping supplies gas to the building without having a curb valve or service valve. What is stamped on a tag near the service meter indicating there is no curb valve or service valve?
NC
What is stamped on a tag near the service meter indicating an excess flow valve exists in line on the service pipe.
EFV. The EFV should limit or stop excess flow down pressure from it
What is another name for a curb valve?
Service valve
Exterior Gas service valves control the supply of gas to meters installed where? If an exterior gas service valve is present is there a curb valve/service valve?
Outside of the building. If an Exterior gas service valve is present, no curb valve/service valve is required
Head of service valves control the supply of gas to meters where?
Inside of buildings
typical house appliance pressure is how much? A few commercial customers receive gas at what psi?
1/4 psi; 1 to 3 psi
There are a small number of large facilities that utilize full line pressure, especially for power generation
Service regulators are usually located _______ The gas meter on_________ Systems to reduce gas flow to low pressure (1/4 psi)
Before; medium and high pressure
Pack vents are installed on system supplied by_________To vent excess gas to the exterior if the service regulator fails. They may have a white color?
Medium or high pressure; Red Cap. There should normally be no odor of natural gas and a Peck fan. If an odor is detected, you must investigate to determine the source
Gas meters can’t supply individual occupancy’s or entire buildings. The quarter turn meter valve that controls the supply of natural gas to the meter is before or after the meter?
Before the meter there should be a quarter turn meter valve that controls the supply of natural gas to the meter
Some multi occupancy buildings have only a single master meter. Shutting it down will shut gas to the entire building. Sometimes utility company will have two master meters adjacent to one another so a master meter can be serviced or replaced without interrupting service to the building. To shut supply to the building which meter or meters have to be shut?
The valves to both meters would need to be closed the shut supply to the building
Some older apartment buildings may have individual gas meters located inside of each apartment served, and in some buildings, meters may be found in the public hallway. The presence of gas piping or meters in a public hallway requires what?
Appropriate enforcement action refer to the BISP manual
Often there are interior gas riser valves coming off the master meter, where are they typically found?
Near the ceiling of the cellar. These can be used to isolate a section of the building instead of sharing service to the entire building.
All natural gas appliances should have a 1/4 valve between them in the building/tenant natural gas supply pipe. The pipe connecting the appliance to the supply pipe is?
Rigid or flexible.
Commonly found natural gas appliances include:
Stove/oven’s, barbecues, refrigeration, dryer’s, hot water heaters, Window/ wall-mounted gas heaters, fireplaces, Outside decorative lighting
When it comes to air conditioners, large commercial units are often located where?
Rooftops or setbacks. Some HVAC units are combination units, housing heating units using natural gas and conventional cooling units.
True or false. In the past, natural gas was used for illumination inside of certain buildings. These old gas lines were sealed with wax and, overtime, this wax can deteriorate resulting in a gas leak. These types of leaks may be difficult to locate
True
Direct vent appliances; direct vent boilers and hot water heaters have become prevalent throughout the city. They may be located where within a structure? and are vented by a short length of pipe through which wall?
Anywhere within a structure; vented by a short length of pipe through an exterior wall. Direct vent window and through the wall heaters may also be used to heat individual occupancy’s
On occasion a response can elevate to a major gas emergency, at which point Fdny strategy should focus on what?
Life safety evacuation
The following conditions are indicative of a major gas emergency
Serious damage to major components of the gas infrastructure I. E. A master meter servicing many appliances, guest service pipe, main valves, distribution means, etc
•
What percent LEL or greater detected outside or inside could be an indicator of of a major gas emergency?
10% LEL or greater
Elevated natural gas readings in an unvented, sub surface structure E. I. Manhole, sewer, etc. of what percent LEL isn’t indicative of a major gas emergency?
20% LEL or greater
Guess present in how many subsurface structures isn’t indicative of a major gas emergency?
Two or more