Elevator-Cali Test Flashcards
What Code section covers Alterations?
8.7
What Code Section Covers Seismic
8.4
What Code Section Covers VRC
Title 8 Elevator Safety Orders (Group 2 Article 12.5)
What Code section covers VPL
ASME A18.1 2003 (Section 2)
What part does not need division approval
Controller
What needs to be submitted to the division before work begins
letter of intent
When was ASME A17.1 2004 adopted by the state Of California
May 1, 2008
How often are category 1 inspections performed
Annually
Phase 1 and one floor Phase 2 are tested how often
monthly
what are the key positions for phase 1
Reset, Off, On
What groups require a five year load test
Group 2,3,4
When was group 3 adopted
October 25, 1998
What is the max width of a single vision panel
6 inches
Laminated Platforms are permitted with a rated load of what
5,000lbs or less
Car enclosures if made of openwork shall reject a ball of what size
1 inch
pull straps heights for group 4
79 inches
spaces containing secondary, deflecting sheaves and governors shall have a height of what
53 inches
machine room doors shall have a minimum dimension of
80” x 29.5”
access doors size not requiring bodily entry
24 x 24
what is the minimum dimensions of an elevator entrance
80” x 31.5”
When a car rest on a fully compressed buffer, what is the minimum vertical clearance between the pit and the car
24 inches
Mainline power shall be disconnected upon or prior to activation of fire sprinklers when sprinklers are installed at what height
24” or more above pit or machine room floor
When the hoist way has fire sprinklers, all electrical shall be NEMA 4 When installed at what height
less than 48” above the pit floor
The light switch for the machine room shall be located where
Lock side of the door